Electrical Requirements
The following power supply must be provided:
DOMESTIC UNITS:
120/208 or 120/240 V~, 60 Hz
(reference unit Data Plate for Wattage requirement)
Twin Models have two kettles and two plugs (one for each side of popper) and include two
wall receptacles.
32 oz. Kettle Models
are designed to operate on single phase, 30 AMP, 4 wire supply,
120/208 or 120/240 V~ (2 Hot, 1 Neutral, 1 Ground). All electrical components in this
machine are 120 V (motors, heat elements, lights, etc.) and ther
efore require “Hot to Neutral”
connection (
NOT
“Hot to Hot”). A 30 AMP wall receptacle (NEMA L14
-30) is supplied with
the unit
—
it accepts the attachment plug on the machine and must be used. Reference the
Receptacle Wiring Diagram for NEMA L14-30 for receptacle installation instructions.
52 oz. Kettle Models
are designed to operate on single phase, 50 AMP, 4 wire supply,
120/208 or 120/240 V~ (2 Hot, 1 Neutral, 1 Ground). All electrical components in this
machine are 120 V (motors, heat elements, light
s, etc.) and therefore require “Hot to
Neutral” connection (
NOT
“Hot to Hot”). A 50 AMP wall receptacle (
NEMA 14-50) is
supplied with the machine. The receptacle will accept the attachment plug on the machine
and must be used; reference the Receptacle Wiring Diagram for NEMA 14-50 for receptacle
installation instructions.
EXPORT UNITS:
220-230 V~, 50/60 Hz
(reference unit Data Plate for Wattage requirement)
Potential Electrical Variations: 220 V~, 60 Hz
Twin Models have two kettles and two plugs (one for each side of popper).
Export units
are designed to operate on single phase, 16 AMP, 4 wire supply, 230 V~
(2 Hot, 1 Neutral, 1 Ground). All electrical components in this machine are 230 V (motors,
heat elements, lights, etc.) and therefore require
“Hot to Neutral” connection (
NOT
“Hot to
Hot”). A certified electrician must supply and install the wall receptacle for this unit;
reference the Receptacle Wiring Diagram for Export Units.
Australia - 52 oz. units
are designed to operate on single phase, 36 AMP, 2 wire supply, plus
ground. All electrical components in machine are 230 V (motors, heat elements, lights,
etc.) A certified electrician must supply and install the wall receptacle for this unit.
DANGER
Machine must be properly grounded to prevent electrical shock to personnel.
Failure to do so could result in serious injury, or death.
DO NOT immerse any part of this equipment in water.
DO NOT use excessive water when cleaning.
Keep cord and plug off the ground and away from moisture.
Always unplug the equipment before cleaning or servicing.
Make sure all machine switches are in the OFF position before plugging the
equipment into the receptacle.