Operating your Dehumidifier 

WATER TANK FULL 
A  beep  signal  will  sound  15  times.  The  WATER 
FULL  indicator  light  will  illuminate  on  the  control 
panel.   
The compressor will stop automatically, and the unit 
will stop dehumidifying. 

Empty the water container and replace it in the 
correct position. If the drainage tank is dirty, wash it 
with cold or lukewarm water. Do not use detergent, 
scouring pads, chemically treated dust cloths, 
gasoline, benzene, thinner, or other solvents, as 
these can scratch and damage the tank and cause 
water leakage  

When replacing the drainage tank, press the tank 
firmly into place with both hands. If the tank is not 
positioned properly, the “TANK FULL” sensor will be 
activated, and the dehumidifier will not operate. 

Do not remove the float from the water tank. The 
water full sensor will no longer be able to detect the 
water level correctly without the float and water may 
leak from the water tank. 

 
The  Dehumidifier  will  continue  dehumidifying  when 
the 

compressor 

automatically 

restarts 

after 

approximately three minutes. 
 
 
To  turn  the  Dehumidifier  off,  press  the  POWER 
button. 
 
 
If the Dehumidifier is switched off and then switched 
back  on,  the  compressor  will  start  to  operate  after 
three minutes. 
 
 
 
 

WARNING Keep all objects at least 1 metre 
from the front, sides and rear of the appliance.

 

 

WARNING: In order to avoid overheating, do 
not cover the appliance. 
 
WARNING: Never leave this appliance 
unattended. 

 
Leave  the  appliance  to  stand  for  one  hour  after 
transport or after the unit has been on its side before 
connecting it to the mains supply to let the refrigerant 
settle. 

 

Ensure  that  the  water  container  is  positioned 
correctly. 

 

Ensure  all  external  windows  and  doors  are  closed 
before turning on the unit. 
 

Plug  into  power  supply  and  switch  on  at  the  mains.  
The dehumidifier will display the current humidity level 
on  the  control  panel.  The  POWER  indicator  light  will 
illuminate to show power to the unit.  

The  louvre  to  be  opened  by  lifting  the  louvre  at  the 
opening and pushing it upward. 

 

To  turn  the  Dehumidifier  on,  press  the  POWER 
button.  

 

 

 

 

 

 

 

As  long  as  the  water  container  is  not  full,  the 
Dehumidifier  will  continue  to  operate  until  it  is 
switched off manually. 
 
 

Always  choose  a  safe  location  for  the  Dehumidifier,  keeping  in  mind  the 
safety  precautions  outlined.  Ensure  all  packaging  has  been  removed  from 
the unit before use. This appliance requires no installation, it should be used 
solely as a portable appliance. 

Attention: This Dehumidifier is rated to extract 10L per day in an environment of 80% humidity and 
temperature of 30°C. This is the world-wide standard for rating dehumidifiers. In NZ we do not have climatic 
conditions with this humidity and high temperature. Accordingly this product will not extract 10L per day, 
extraction levels will be lower. 

 

This dehumidifier is designed to provide optimum performance at 35°C -15°C but it is still effective down to 
5°C. Ultimately the performance of this dehumidifier is dependant on the amount of moisture or water vapour 
in the air. 

 

Summary of Contents for GSD180

Page 1: ......

Page 2: ...ctrical person for examination electrical service or repair 17 Do not twist kink or wrap the cord around the appliance as this may cause the insulation to weaken and split Always ensure that all cord has been removed from any cord storage area and is unrolled before use 18 It is recommended that this appliance is plugged directly into the wall socket Power boards are not rated to supply power to h...

Page 3: ... 9 Supply cord Attention This Dehumidifier is rated to extract 10L per day in an environment of 80 humidity and temperature of 30 C This is the world wide standard for rating dehumidifiers In New Zealand we do not have climatic conditions with this humidity and high temperature Accordingly the extraction levels will be lower ...

Page 4: ...liance unattended Leave the appliance to stand for one hour after transport or after the unit has been on its side before connecting it to the mains supply to let the refrigerant settle Ensure that the water container is positioned correctly Ensure all external windows and doors are closed before turning on the unit Plug into power supply and switch on at the mains The dehumidifier will display th...

Page 5: ...down completely before cleaning Use a damp cloth not wet to wipe the exterior of the Dehumidifier to remove dust and dirt Use a vacuum cleaner to remove dust and fluff from around the grills Never use solutions such as benzene thinners or polishing agents Ensure the Dehumidifier is dry before plugging back into the mains supply TO CLEAN THE AIR FILTER Unplug the Dehumidifier from the mains supply ...

Page 6: ...oesn t work Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Is the intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct No air is discharged Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Operation is noisy Is the unit tilted or unsteady Move the unit to a st...

Page 7: ...under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantees...

Page 8: ......

Reviews: