3
TO INSTALL LINEAR BURNER:
1.
Attach damper clamp to fireplace damper to
prevent damper from being fully closed.
2.
Position burner assembly into fireplace and
position in center of floor.
3.
Attach Gas connector to gas supply line and
connect to burner assembly. Use soapy water to
check connections for leaks. (Figure 3-1)
4.
Pour silica sand into burner pan completely
covering pipe in pan. For LP Gas models, use
vermiculite instead of sand. (Figure 3-2)
NOTE! Optional decorative fireglass can be
susbstituted for silica sand or vermiculite (LP) for
a more contemporary design if desired
(Figure 3-5).
5.
Place glowing ember material over sand
(Vermiculite LP). (Figure 3-3) Note: Not used if
optional decorative fireglass is used.
Spread the black volcanic cinders in front of and
on sides of Linear Burner (Figure 3-4)
NOTE! Optional Decorative Fireglass can also
be used in place of black volcanic cinders.
(Figure 3-5)
YOU ARE NOW READY TO LIGHT THE BURNER BY TURNING THE FIREPLACE GAS VALVE ON AND USING A
LONG MATCH OR BUTANE LOG LIGHTER. LIGHT THE BURNER BY POSITIONING MATCH OR LIGHTER JUST
OVER BURNER WHILE TURNING ON THE GAS VALVE. DURING THE FIRST FEW HOURS OF OPERATION, AN
OCASSIONAL POPPING SOUND CAN BE HEARD AS A RESULT OF THE METAL EXPANDING FROM HEAT. THIS
WILL STOP AFTER A SHORT PERIOD OF TIME.
Lighting instructions for “Alpine Linear
Burners” with a millivolt, spark to pilot,
or S-model “Skytech Hi/Lo” valve located
on subsequent pages of this manual.
Figure 3-1
Figure 3-2
Figure 3-3
Figure 3-4
Figure 3-5
DAMPER MUST BE IN FULL OPEN POSITION