LIGHTING INSTRUCTIONS FOR

“S-MODEL” SKYTECH REMOTE HI-LO MOTOR MODELS

To Turn OFF Gas To Appliance
1.

Turn off switch or remote.

2.

Remove Decorative Front

3.

Turn control knob clockwise to “PILOT”

4.

Depress control knob slightly and turn
clockwise to “OFF”

A.

The Golden Blount appliance has a pilot which must
be lit by hand. When lighting the pilot, follow these
instructions exactly.

B.

Before Lighting, smell all around the area for gas. Be
sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch, do not use any

phone in your building.

Immediately call your gas supplier from your

neighbor’s phone. Follow the gas supplier’s
instructions.

If you cannot reach your gas supplier, call the fire

department.

C.

Use only your hand to push in or turn gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don’t try to repair it. Call a qualified
service technician. Force or attempted repair may
result in fire or explosion.

D.

Do not use the appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance set and to replace any part of
the control system and any gas control system and
any gas control which has been under water.

E.

FIREPLACE DAMPER MUST BE FULLY OPENED.

FOR YOUR SAFETY,

READ BEFORE LIGHTING

Pilot Burner Location

Decorative Front

Screw

Remote Control

Connector

1.

“Stop!”

 First read the safety information

at the left.

2. Remove two screws from sides of burner

and take off decorative front to access
control valve.

3. Turn the control to the “OFF” position. To do

this, you must turn the knob clockwise
to the “PILOT” position and then press
in and continue turning clockwise         to the
“OFF” position.

4.

WAIT FIVE (5) MINUTES TO CLEAR
OUT ANY GAS.

If you then smell gas, STOP! Follow step
“B” in the safety information at the left. If
you don’t smell gas, go to the next step.

5. To put the control in the pilot position, turn

the control knob counter-clockwise       to
the“PILOT” position.

6. To light the pilot, depress the control knob

and light the pilot using a long match or
extended butane lighter. The control knob
should be held IN for 1 minute.

7. Release the control knob. The pilot should

remain lit after releasing.

8. Turn the control knob counter-clockwise

to the “ON” position.

9. Connect RCAF-1031 Remote control

receiver to connector on control valve and
position receiver behind burner assembly
on floor of fireplace.

10. Replace decorative front and follow

operation instructions supplied with
RCAF-1031 Remote Control.

I G

A

A

I G

WARNING:

WARNING:

 IF YOU DO NOT FOLLOW

THESE INSTRUCTIONS EXACTLY, A FIRE

OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY

OR LOSS OF LIFE

Control

Knob

Summary of Contents for ALB24NAT

Page 1: ...as supply piping system when testing at test pressures in excess of 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of gas supply system at test pressures equal to or less than 1 2 psig This is accomplished by closing the gas supply line valve which is required by NFPA 54 section 5 54 The minimum i...

Page 2: ...UM FIREBOX MINIMUM BTU HR WIDTH AT 7 DEEP REQUIRED FROM FRONT FIREBOX DEPTH ALB24NAT 26 20 22 500 ALB30NAT 32 20 25 250 ALB36NAT 38 22 34 000 ALB24NAT 26 22 20 500 ALB30LP 32 22 31 000 ALB36LP 38 22 37 750 The gas fittings supplied are for what the factory considers a normal installation Some installations may require a longer connector tube or other fittings available in most hardware stores 1 ...

Page 3: ...optional decorative fireglass is used Spread the black volcanic cinders in front of and on sides of Linear Burner Figure 3 4 NOTE Optional Decorative Fireglass can also be used in place of black volcanic cinders Figure 3 5 YOU ARE NOW READY TO LIGHT THE BURNER BY TURNING THE FIREPLACE GAS VALVE ON AND USING A LONG MATCH OR BUTANE LOG LIGHTER LIGHT THE BURNER BY POSITIONING MATCH OR LIGHTER JUST OV...

Page 4: ... control which has been under water E FIREPLACE DAMPER MUST BE FULLY OPENED FOR YOUR SAFETY READ BEFORE LIGHTING Pilot Burner Location Decorative Front Screw Remote Control Connector 1 Stop First read the safety information at the left 2 Remove two screws from sides of burner and take off decorative front to access control valve 3 Turn the control to the OFF position To do this you must turn the k...

Page 5: ...SING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY READ BEFORE LIGHTING To Turn OFF Gas To Appliance 1 Turn off switch or remote 2 Remove Decorative Front 3 Turn control knob clockwise to PILOT 4 Depress control knob slightly and turn clockwise to OFF LIGHTING INSTRUCTIONS FOR MILLIVOLT CONTROL VALVE MODELS Decorative Front Screw On Off Switch Pilot Burner Location Gas Control Kn...

Page 6: ... hand don t try to repair it Call a qualified service technician Force or attempted repair may result in fire or explosion D Do not use the appliance if any part has been under water Immediately call a qualified service technician to inspect the gas log set and to replace any part of the control system and any gas control system and any gas control which has been under water E FIREPLACE DAMPER MUS...

Reviews: