To Install Gas Log Set:

  1.

  Attach damper clamp to fireplace damper to  

 

prevent damper from being fully closed.

  2.

  Position burner assembly into fireplace and  

 

position in center and as far toward the rear  

 

as possible (See “Big Tex” Specifications for  

 

allowable dimensions).

  3.

  Attach aluminum connector to gas supply  

 

line and connect to burner assembly. Use  

 

soapy water to check connections for leaks.

  4.

  Pour silica sand into raised rear burner  

 

completely covering pipe in pan. For LP Gas  

 

models, use vermiculite instead of sand.  

 

(Figure 3-1)

  5.

  Place glowing ember material over sand  

 

(vermiculite LP). 

(Figure 3-2)

  6.

  Pour vermiculite over lower adjustable  

 

burner. 

(Figure 3-3)

  7.

  Place glowing ember material over  

 

vermiculite and upward covering sheet  

 

metal deflector. 

(Figure 3-4)

  8.

  Spread the black volcanic cinders in front  

 

of and on sides of adjustable lower burner.  

 

(Figure 3-5)

  9.

  Position bottom front log on grate. Front  

 

log position should be as forward as  

 

possible to allow proper space for flame  

 

carry down tube. (Figure 3-6)

10.

  Position rest of logs on grate using log  

 

arrangement sheet supplied with logs.

Figure 3-1

Figure 3-2

Figure 3-3

Figure 3-4

Figure 3-5

Figure 3-6

YOu ARE NOw READY TO LIGhT ThE LOG SET BY TuRNING ThE FIREPLACE GAS VALVE ON AND uSING A LONG MATCh 
OR BuTANE LOG LIGhTER. LIGhT RAISED REAR BuRNER FIRST BY POSITIONING MATCh OR LIGhTER JuST OVER 
RAISED REAR BuRNER whILE TuRNING ON GAS VALVE. AFTER RAISED REAR BuRNER LIGhTS, YOu CAN uSE CONTROL 
TOOL FOR LOwER ADJuSTABLE BuRNER TO DESIRED FLAME hEIGhT. A MODERATE FIRE DuRING ThE FIRST 4 hOuRS 
OF BuRN TIME IS RECOMMENDED. DO NOT OVERFIRE AT ANYTIME.

DAMPER MUST BE IN FULL OPEN POSITION  

BEFORE LIGHTING

Summary of Contents for BIG TEX BT24

Page 1: ...with doors in open position Do not burn wood or other items with log set FOR YOUR SAFETY If you smell gas 1 Open Windows 2 Don t Touch electrical switches 3 Extinguish any open flame 4 Immediately call your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance The installation including provisions for combusti...

Page 2: ... Embers 4 Black Volcanic Cinders 5 Vermiculite Used in raised rear burner LP Gas and used on top of lower adjustable burner Nat LP Gas 6 Gas Connector 7 Damper Clamp 8 Control Tool Adjustable lower burner 2 1 4 3 5 6 7 8 L P SETS MUST INCLUDE GB FACTORY INSTALLED SAFETY PILOT KIT NOTE Big Tex ceramic gas logs are packaged in separate cartons Individual logs and log arranage ment instructions are s...

Page 3: ...3 2 6 Pour vermiculite over lower adjustable burner Figure 3 3 7 Place glowing ember material over vermiculite and upward covering sheet metal deflector Figure 3 4 8 Spread the black volcanic cinders in front of and on sides of adjustable lower burner Figure 3 5 9 Position bottom front log on grate Front log position should be as forward as possible to allow proper space for flame carry down tube ...

Page 4: ...ST BE FULLY OPENED 1 Turn the gas control knob counter clockwise to the PILOT position push the gas control valve IN and HOLD in position This will open the pilot valve and allow gas to flow to the pilot burner 2 Light the pilot burner while holding the gas control knob in until a strong pilot flame is present approximately 60 seconds 3 Release the gas control knob The gas control knob will hold i...

Page 5: ...rner location Nat Gas models Gas Control Knob FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A The Golden Blount Gas Log Set has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the gas...

Page 6: ...ot cover parts subjected to misuse abuse improper handling or improper installation The GB warranty specifically excludes any liability for indirect incidental or conse quential damage to property Defective logs or defective parts should be returned to your dealer or to the factory prepaid with a copy of your sales receipt Defective parts will be repaired or replaced at the factory s option and re...

Reviews: