Finishing the Wall
Finish the wall with the material
of your choice. Do not install a
combustible mantle or other
combustible projection above the
opening unless it is a
minimum of 12 inches above top
of
opening. (Figure 10.1)
CAUTION:
All joints between the
wall and the
surround (Top and
Sides) can only be sealed with non-combustible material. Only non-combustible
material can be applied as facing to the
surround. (Figure 10.1)
Hearth Extension
A Hearth Extension may be installed. But it is not required for vented gas
Glass Installation LFP4218
1.
Model LFP4218 is supplied with 15 lbs of
that is used to
burner
tray and be distributed around the surrounding
area of the
2.
Fill burner tray with glass even with or slightly above
of
(Figure 9.1).
3.
Distribute remaining glass around front, sides and rear of burner tray covering
area. (Figures 10.2-11.1)
STUD
2X4
HEADER
FINISHED
WALL
NON-COMBUSTIBLE
SEAL JOINT
MANTLE
12" MIN
TOP OF
OPENING
Figure 10.1
Figure 10.2
10
GLASS INSTALLATION (optional)
1. All LFP MODELS can be used with approved Fireglass to enhance the overall appearance.
2. Fill the burner tray below and up to the top of the burner ports. Do not cover burner ports.
3. Distribute additional glass around front, sides and rear of burner tray, covering floor area.
(Figures 10.2-11.1)
Note: Model LFP4218 Includes 15 Lbs. of Fireglass