15
TO TURN OFF GAS TO APPLIANCE
1.
Turn ON/OFF rocker switch to “OFF”
2.
Remove batteries from appliance if service is to be performed.
LPG (PROPANE) WARNING
THE FOLLOWING WARNING APPLIES TO INSTALLATIONS USING L.P. (PROPANE GAS):
WARNING: To avoid possible injury,
and explosion, please read and follow these precautions
and all instructions of this appliance before operating. This appliance uses L.P. (Propane)
gas which is heavier than air and will remain at the
level is there is a leak. Before lighting,
smell at
level and/or use other means (such as using a soap solution on all piping and
connections, using a gas detector, etc.) to check for gas leaks. NOTE: L.P. (Propane) gas can
become odorless and CANNOT always be detected by smell. If you smell gas, detect a gas leak or
suspect that a gas leak exists, follow these rules:
1. Get all people out of building.
2. DO NOT light matches. DO NOT turn electric lights or switches on or off in area. DO NOT use
an electric fan to remove gas from area. DO NOT use a telephone inside of building.
3.
Shut off gas at L.P. tank outside of building.
4.
Telephone gas company and
department. Ask instructions. Before hanging up, give your
name, address and phone number. DO NOT go back into building.
If your L.P. tank runs out of fuel, turn off gas at the appliance. After L.P. tank is
appliance
must be re-lit according to manufacturer’s instructions. If The gas control has been exposed to
WATER in any way, DO NOT try to use it. It must be replaced. DO NOT attempt repair on gas
control or appliance.
Tampering is DANGEROUS and voids all warranties. Any component that is found to be faulty,
must be replaced with an approved component.
TO TURN OFF GAS TO APPLIANCE
IMPORTANT: Always keep the appliance area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance
clear of all obstacles and materials.
To obtain proper operation, it is imperative that the pilot and main burner flame
characteristics are steady, not lifting or floating. Typically the top 1/4 Inch of the flame
sensor should be engulfed in the pilot flame. (Figure 12.2)