BUILDING CODES AND SAFETY STANDARDS
4
NOTE:
INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE
PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING
MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT THE UNITS CONTROL COMPARTMENT,
BURNERS, AND CIRCULATING AIR PASSAGE-WAYS BE KEPT CLEAN TO PROVIDE
ADEQUATE COMBUSTION AND VENTILATION AIR.
CLEARANCES REQUIRED
MINIMUM CLEARANCES FOR THE FIREBOX ARE:
1/2" ON THE SIDES AND BACK AND 0 AT THE BOTTOM. TOP CLEARANCE IS 3"
.
NOTE:
PROVIDE ADEQUATE CLEARANCES AROUND AIR OPENINGS INTO THE
COMBUSTION CHAMBER.
NOTE:
ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND PROPER
OPERATION MUST BE PROVIDED IN ACCORDANCE WITH ANSI Z21.50-2014.
The design of this FIREPLACE has been tested and is listed
with PFS CORPORATION
in accordance with THE AMERICAN NATIONAL STANDARDS INSTITUTE —
ANSI Z21.50-2014.
This manual serves only as a basic guideline for installation and use of this
and gas piping. The complete installation must be in accordance with local codes and
ordinances, or, in the absence of local codes, with the American National Standards
Institute National Fuel Gas Code Z223.1 latest edition.
GENERAL INFORMATION
MODEL
LFP9618 IS A
TOP VENTED GAS FIREPLACE.
IT IS
DESIGNED TO BURN BY
DRAWING COMBUSTION AIR FROM THE OUTSIDE AIR KIT THAT ATTACHES TO THE SIDE
(SIDES) OF THE FIREPLACE.
THE EXHAUST FLUE GASES ARE TO BE VENTED THROUGH THE TOP-VENT USING
10"
B-TYPE GAS VENT PIPE
,
ASSISTED BY AN APPROVED POWER VENT
EXHAU
S
T
FAN
.
THE CONTROL SYSTEM IS A (3V) SPARK TO PILOT TYPE THAT INCLUDES A
ON-OFF SHUTOFF VALVE, A GAS CONTROL VALVE, A SPARK TO PILOT LIGHT
ASSEMBLY, AND ON-OFF ROCKER SWITCH.
WARNING:
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.