Installing Chimney/Vent System
7
MINIMUM FRAMING DIMENSIONS PRIOR TO POSITIONING UNIT
FINISHED FRAMING DIMENSIONS WITH UNIT IN POSITION
NOTE: DIMENSIONS PRIOR TO POSITIONING FIREPLACE ALLOWS
CLEARANCE FOR OUTSIDE AIR COLLARS AS WELL AS FIREPLACE
HEADER TO BE NAILED AT CORRECT HEIGHT AFTER BOX HAS
BEEN SET.
11”
TOP
VIEW
FIREPLACE IS
POSITIONED
MINIMUM
FRAMING
DIMENSIONS
52 1/2"
5
2"
30 1/2"
INSTALLED AFTER
INSTALLED AFTER
FIREPLACE IS
POSITIONED
24”
32”
55 1/4"
Figure
7.1
18”
52 1/4"
4 1/8”
29”
2 1/2”
6 1/2”
23 1/2”
4”
7”
111
”W X
55 1/4
”H X 24” D
106
”W X 32”H X 24”D
A
B
C
D
MIN
IMUM
FRAMING DIMENSIONS LFP
9618
LFP
96
18
A
106
"
B
111
"
C
9
6"
D
104
3/4"
Model LFP
96
18
is
approved to
be used with
10"
B-Type Gas Vent.
The Fireplace must be installed with an Enervex
Model RS 14 Exhaust Fan, PDS-1 or ADC-100 Draft Switch that is connected to this Fireplace.
WARNING:
This Fireplace must not be installed without Exhaust Fan, Golden Blount, Inc. can supply the
Enervex
products or they can be purchased through a third party supplier.
WARNING:
A Proven Draft Switch must be installed with the Exhaust Fan and connected to this Fireplace. A
Proven Draft Switch will prevent this fireplace from operating if the Exhaust Fan is not providing proper e
vacuation
of
flue gases.
Note: Detailed instructions for Enervex Exhaust Fan, Power Draft Switch installation is included in the
Enervex Products.