As
a
general
rule,
on
lower
feed
rate
settings,
the
damper
should
be
in
farther.
On
higher
feed
rates,
the
damper
should
be
more
open.
Through
trial
and
error,
you
will
find
the
best
setting.
NOTE:
On
“1”,
damper
should
be
either
completely
closed
or
out
approximately
⅛
”
to
¼”.
If
damper
is
out
too
far,
it
can
cause
the
fire
to
go
out.
OPENING
DOOR
If
the
door
is
opened
while
the
stove
is
in
operation
it
must
be
closed
within
30
seconds
or
the
stove
will
shut
down.
If
the
stove
shuts
down
push
the
“On/Off”
button
to
re
‐
start
your
stove.
ROOM
AIR
FAN
When
starting
your
stove
the
Room
Air
Fan
will
not
come
on
until
the
stove’s
heat
exchanger
warms
up.
This
usually
takes
about
10
minutes
from
start
‐
up.
RE
STARTING
A
WARM
STOVE
If
the
stove
has
been
shut
off,
and
you
want
to
re
‐
start
it
while
it
is
still
warm,
the
“on/off”
button
must
be
held
down
for
2
seconds.
IF
STOVE
RUNS
OUT
OF
PELLETS
The
fire
goes
out
and
the
auger
motor
and
blowers
will
run
until
the
stove
cools.
This
will
take
30
to
45
minutes.
After
the
stove
components
stop
running
the
“On/Off”
and
the
BAR
GRAPH
lights
stay
on
for
10
minutes.
After
the
10
minutes
the
“3”
light
on
the
bar
graph
will
flash
and
the
“On/Off”
light
will
go
off.
To
restart,
refill
hopper
and
press
“Fuel
Feed”
button
until
pellets
begin
to
fall
into
burnpot.
Press
“On/Off”
button.
REFUELING
We
recommend
that
you
not
let
the
hopper
drop
below
¼
full.
KEEP
HOPPER
LID
CLOSED
AT
ALL
TIMES
EXCEPT
WHEN
REFILLING.
DO
NOT
OVERFILL
HOPPER.
STOVE
MAINTENANCE
TOOL
A
tool
has
been
provided
to
help
with
the
following
functions:
a.
Stirring
pellets
in
hopper
–
unlike
liquids
in
a
tank,
pellets
do
not
drain
evenly
into
the
auger.
Bridging
across
the
opening
can
occur.
Pellets
can
hang
up
on
the
sides
of
the
hopper.
Occasionally
“stirring”
the
hopper
can
help.
b.
Scrape
ashes
from
burnpot.
Summary of Contents for MONROE