background image

Golden Mask

5+

User Guide

18 kHz
BITONAL
GB 30

GAIN 1
THRESHOLD 25
P.BOX LOW

+

69

IRON

FOIL NICKEL COPPER SILVER

Summary of Contents for 5+

Page 1: ...Golden Mask 5 User Guide 18 kHz BITONAL GB 30 GAIN 1 THRESHOLD 25 P BOX LOW 69 IRON FOIL NICKEL COPPER SILVER...

Page 2: ...dual frequency coils Wireless headphones WS105 included in the package 5 years warranty of the electronics board To offer the 5 years warranty the Golden Mask metal detectors are made with only top le...

Page 3: ...ly from the handle part but we do not recoomend it because a plactic shim inside the locking screw could be lost or damaged Please be sure to have a minimum of 15 cm 6 inch of the third section inside...

Page 4: ...he ENTER button A reset is REQUIRED every time after you change the working frequency or the PowerBox settings If the surrounding temperature is changing quickly the detector may become nervous In thi...

Page 5: ...bove this border are shown with positive numbers The Iron Audio setting is shown with bi color bar just bellow the Spectrum VDI scale The black part of the Iron Audio bar shows targets that will sound...

Page 6: ...es better the deep iron signals 2 Two tone 2 In two tone or bitonal mode you hear both signals from ferrous and non ferrous targets Ferrous targets are indicated with a low sound while the sound respo...

Page 7: ...select the desired value with the and buttons and confirm with ENTER Ground balance GB The ground balance is a setting that compensates for different ground conditions There are soils with no to very...

Page 8: ...nd Balance To automatically adjust the ground balance press the ground balance GB button on the bottom left corner of the control panel then select the Auto option from the ground bal ance menu and co...

Page 9: ...ptions are 0 1 and 2 The higher the number the greater the overall signal amplification But be aware on mineralization higher number of the Gain does not always mean deeper penetration of the signal O...

Page 10: ...hen try the above two options The PowerBox setting is related to the working frequency In other words you could set different values for the two working frequencies The detector will remember the sett...

Page 11: ...activated a small icon appears below the battery icon on the main screen to show you the backlight is on when Controlling the LCD screen contrast You can change the LCD screen contrast To do this sho...

Page 12: ...e Automatically adjust from 6V 15V Max voltage with no load 20V Rated Current 500mA 450mA 600mA Trickle Current 35 50MmA Pulsel ratio 1 20 10mA Short Circuit Current 10 20mA Battery repairingl Current...

Page 13: ...ference EMI fields that will disturb the detector and you may think something s wrong On sites with not too many targets try to use the All metal mode this will give you 2 3 cm more depth If you canno...

Page 14: ...Golden Mask 5 User Guide GMD www goldenmaskdetectors com Golden Mask Official Distributor 26...

Reviews: