4. Electrical Wiring (page 10)
Main service
Grounding and bonding
Circuit breakers
Pro Logic control power
High Voltage pool equipment
Low voltage wiring (temperature sensors, flow
switch, etc.)
2
29
ºC ºF
Ti
Calcuim
Hardness
Ci
Total
Alkalinity
Ai
53
60
66
76
84
94
103
12
16
19
24
29
34
39
.3
.4
.5
.6
.7
.8
.9
How to use:
Measure pool pH, temperature, calcium hardness,
and total alkalinity. Use the chart above to determine Ti, Ci,and
Ai from your measurements. Insert values of pH, Ti, Ci and Ai
into the above equation. If Si equals .2 or more, scaling and
staining may occur. If Si equals -.2 or less corrosion or irritation
may occur.
Si = pH + Ti + Ci + Ai - 12.1
-.2
0
.2
CORROSIVE
SCALING
75
75
100
100
125
125
150
150
200
200
250
250
300
300
400
400
600
600
800
800
1.5
1.9
1.6
2.0
1.7
2.1
1.8
2.2
1.9
2.3
2.0
2.4
2.1
2.5
2.2
2.6
2.4
2.8
2.5
2.9
OK
Time Format
12 hour AM/PM
Units
ºF and PPM
Move to previous/next configuration menu
Move to previous/next configuration menu
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options
Reset Config. to
Default Press +
Are you sure?
+ to proceed
Config. reset
Confirmed
Initiate reset of all configuration parameters
Reset all configuration parameters
Move to previous/next configuration menu (config. not reset)
Move to previous/next menu (config. not reset)
Move to previous/next configuration menu
Use this function to erase all previous system configuration and reset all configuration parameters back to
the factory default values. This function is NOT reversible--be careful.
Maintenance Menu
(only displays if Sensing System is enabled)
The Maintenance Menu will be displayed only if the optional AQL-CHEM is used and the Sensing System is enabled
in the Chemistry Config. Wizard. This menu is used to perform functions relating to the AQL-CHEM ORP and pH
sensing kit.
pH Calibration
Wizard, + to enter
Push to access pH Calibration Wizard
Move to previous/next menu item
Use this Wizard to calibrate the AQL-CHEM’s pH probe. This requires a manual pH test of the pool water
using a dependable red phenol test kit.
Clean Probe Wizard
+ to enter
Push to access Clean Probe Wizard
Move to previous/next menu item
Use this Wizard to clean the AQL-CHEM’s ORP and pH probes. The probes must be clean and free from oil,
chemical deposits and contamination to function properly. Slow response, increased need to calibrate,
and inconsistent readings are indications that the probes need to be cleaned.
5. Pro Logic control configuration (page 20)
6. System Startup and checkout (page30)
1. Preparing Pool/Spa Water
General Water Chemistry
Salt is required only if you are using the chlorinator features on the Pro Logic Control. If you are NOT using the
chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to the
description of the Pro Logic configuration menu for information on enabling/disabling the chlorinator (see page 20).
Water Chemistry
The table below summarizes the levels that are recommended by the Association of Pool and Spa Professionals
(APSP). The only special requirements for the Pro Logic are the salt level and stabilizer.
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water “bal-
ance”. Your water is properly balanced if the Si is 0 ±0.2. If the Si is below -0.2, the water is corrosive and plaster
pool walls will be dissolved into the water. If the Si is above +0.2, scaling and staining will occur. Use the chart below
to determine the saturation index.