IP G+
www.golmar.es
3.4. Installation
7” HAND FREE VIDEO DOOR PHONE
POWER SOURCE: DC 12V/POE 18V
+12V GND
SA
RJ 45
DC-12V
GND
FPOE
SPOE
SA
GND
GND
48V
18V
3.2. Back side
RJ45 connector.
The guard unit is a device that is easy to install and program, it does not require a computer or specific knowledge about networks to set
it up. First, we must connect the guard unit to the network connecting it to an output of the D4L-G+/PoE, after a DCS/G+ if the network
topology is a daisy-chain or an own power supply at 12Vcc. Remember that, when connecting to a power supply, yo must connect the
guard unit to an UP-LINK output of the switch so that is connected to the network.
Once completed the netwrok connection, it will start automatically and the initial configuration screen will appear.
Output for auxiliary sounder.
Input for 8 alarms.
Connector for power supply at 12V.
See an installation as an example where there are connected to each other a 6502/G+ coded panel, an ART 7/G+ monitor and a
CE-ART7/G+ guard unit. As you can see, the guard unit is connected to one of the D4L-G+ distributor output so that it is not necessary
to connect it to an external power supply.
Supply voltage jumper.
3.4.Jumper description
Jumper allows to select which voltage range supplies the device, as is not the same voltage when the device is connected to a D4L-G+/PoE
switch output than if it is connected to a 48V PoE standard switch.
- Position 48 (default).
Device is ready to receive 48V standard PoE.
- Position 18.
Device is ready to receive 18V from a D4L-G+/PoE switch.