Digital relay for

and

systems, which permits the following operation modes:

Relay for additional call repeater.
Relay for 2nd door Lock release.
Bus relay.

Need to configure or program depending on the mode of operation.
Can be installed at any point of installation (see operation modes).
It connects directly to the bus as another element of the installation.
Easily configurable through easy access microswitch.
Programming status led.
Jumper JP1 selects whether the relay is connected to a

or

system.

Potentiometer PT1 sets the relay operating time.
The maximum current for relay contact will be of 1.8A at 30 Vdc/250 Vac.
The minimum wire section to connect in the relay outputs will be 1.5 mm .
The product includes a fuse of 250V 2A F. Compliance with EN60127-1/EN60127-2 Standards.
The product includes a 120 ohm resistor for End of line (only V2Plus system).
Use Golmar wire

for bus connection to

system.

2PLUS

V2PLUS

2PLUS

V2PLUS

RAP-2150

V2PLUS

Ü
Ü
Ü

2

First of all we would like to thank and congratulate you for the purchase of this product manufactured by
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers. To obtain the maximum profit of these features and a properly wired
installation, we kindly recommend you to expend a few minutes of your time to read this manual.

INDEX

Introduction ...........................................33
Index.....................................................33
System characteristics..............................33
Safety precautions...................................34
Operation modes .......................................

Relay for additional call repeater.............35
Relay for Lock release ............................35
Bus relay .............................................36

Description ............................................37
Installation.................................................

Detail of relay unit installation.................37
Configuration of relay unit .....................38
System selection jumper ........................38
Adjustment potentiometer......................39
Programming Led .................................39
End of line (only V2Plus system)...............39

Programming .............................................

Additional call repeater .........................40

Configuration (2Plus system) ........................

Additional call repeater .........................41
Bus relay .............................................41
Relay for Lock release ............................42

Configuration (V2Plus system) ......................

Additional call repeater .........................43
Bus relay .............................................43
Relay for Lock release ............................44

Installation diagrams...................................

Relay unit (2Plus system) ........................45
Relay unit (V2Plus system) ......................46

Troubleshooting hints ..............................47
Notes...............................................48-50
Compliance...........................................51

F U S E

34

SAFETY PRECAUTIONS

To access the output terminals of the relay, remove the

protection cover using flat pliers, by a light pressure
on the ribs wall and then pull to remove it.

Important:

To avoid an electrical shock, the installation and handling of the relay unit must be performed

by

and in the absence of electrical current.

authorized personnel

Remember:

When the installation and wiring works are finished,

make sure the protection cover and fuseholder are
placed in the relay unit before replacing the electrical
current.

F U S E

Warning:

O

O

O

O

O

O

O

Install the relay unit in a dry and protected place without risk of drip or water projections.
To avoid damage, the relay unit has to be firmly fixed.
The minimum wire section to connect in the relay outputs will be of

.

To avoid an electrical shock, neither remove the protection cover nor handle the connected
wire in the terminals with the symbol

, the installation and handling of the relay unit must

be performed by

and in the absence of electrical current.

In case of blown fuse, replace for one of the same characteristics (see page 33).

The blown fuse must be replaced by

and in the absence of electrical

current.

The maximum current for relay contacts will be of 1.8A at 30 Vdc/250 Vac.
For safety the cover of the fuseholder must always be placed.

1,5mm

authorized personnel

authorized personnel

2

Summary of Contents for SAR-2Plus

Page 1: ...FUSE TSAR 2PLUS ML rev 0110 SAR 2PLUS Digital relay unit instructions manual ...

Page 2: ...ulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our customers is stated through the ISO 9001 certification and for the manufacturing of products like this one Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers To obtain the maximum profit of these fe...

Page 3: ...unit in a dry and protected place without risk of drip or water projections To avoid damage the relay unit has to be firmly fixed The minimum wire section to connect in the relay outputs will be of To avoid an electrical shock neither remove the protection cover nor handle the connected wire in the terminals with the symbol the installation and handling of the relay unit must be performed by and i...

Page 4: ...epeater Call repeater T 7722VD T 7822VD T 7720 Platea V2Plus Platea V2Plus Platea V2Plus T 7822VD 2 220 Vac 1 8A max 2 2 220 Vac 1 8A max 2 Call repeater Call repeater 2 Relay for Lock release The SAR 2Plus unit will work as a Lock release for a second door During call reception or communication process it will be activated together with the Lock release of the door panel by pressing door release ...

Page 5: ...me will range from 3 to 60 seconds depending on the PT1 potentiomenter adjustment during call reception or communication process The neutral supply of the stairs light will be wired through the relay contacts SAR 2Plus V2Plus System 2 2 2 2 2 FA V2Plus 2 2 2Plus System 2 2 2 2 FA Plus C 2 2 SAR 2Plus 2 SAR 2Plus Stairs light activation 2 2 220 Vac 1 8A max 2 2 220 Vac 1 8A max T 7722VD T 7822VD T ...

Page 6: ...it To extract the relay unit from the DIN guide use a plain screwdriver to lever the flange as shown on the picture Install the relay unit in a dry and protected place without risk of drip or water projections DIN 46277 To install the relay unit directly on the wall drill two holes of 6mm diameter and insert the wallplugs Fix the relay unit with the specified screws INSTALLATION 3 5 x 50 DIN 7971 ...

Page 7: ...tart programming mode only to configure SAR 2Plus unit as additional call repeater Once programming is finished set to OFF Description of the system selection jumper JP1 JP1 Insert the jumper in this position if the unit is installed in a Door Entry System 2Plus Factory default Leave all OFF to configure the unit as a bus relay see page 36 No function Insert the jumper in this position if the unit...

Page 8: ... during the tone call and with the potentiometer set to maximum is activated during the time of call plus 45 seconds reproducing the cadence of the call Additional call repeater mode The output activation time will range from 3 to 60 seconds depending on the PT1 potentiomenter adjustment Relay for lock release mode The output activation time will range from 3 to 60 seconds depending on the PT1 pot...

Page 9: ...he same way 2Plus system To program the relay unit as additional call repeater follow these steps Set SW1 1 to ON programming led is OFF Set SW1 3 to ON to enter programming mode Programming led is Blinking Pick the handset up of the monitor phone associated with the relay unit and push door release button The programming led will be set to ON indicating that the relay unit has been programmed Han...

Page 10: ...lay unit will be activated during call reception or communication process by pressing auxiliary push button of any configured phone T 7722VD or T 7822VD of the backbone where the relay unit is installed O O O 2PLUS SAR 2Plus 41 CONFIGURATION SAR 2PLUS NC JP1 E ofLINE BUS BUS NA C BUS F N HZ HZ CALL REPEATER The neutral supply of the additional call repeater will be wired through the relay contacts...

Page 11: ...N see page 38 relay unit will be activated together with the Lock release of the door panel during call reception or communication process by pressing push door release button of any phone of the backbone where the relay unit is installed O O 2PLUS SAR 2Plus 42 CONFIGURATION SAR 2PLUS JP1 AC Lock release TF 104 NC BUS BUS NA C PRI SEC Main SW1 BUS E ofLINE ...

Page 12: ...ption or communication process by pressing auxiliary push button of any configured monitor phone T 7722VD or T 7822VD of the backbone where the relay unit is installed O O O V2PLUS SAR 2Plus SAR 2PLUS NC JP1 BUS BUS NA C PLATEA V2PLUS F N HZ PA PB CALL REPEATER The neutral supply of the additional call repeater will be wired through the relay contacts SAR 2Plus the maximum current for the addition...

Page 13: ...ge 38 relay unit will be activated together with the Lock release of the door panel during call reception or communication process by pressing door release button of any monitor phone of the backbone where the relay unit is installed O O V2PLUS SAR 2Plus AC Lock release TF 104 PRI SEC Main JP1 SAR 2PLUS NC NA C BUS BUS SW1 BUS To the Door Panel CONFIGURATION E ofLINE ...

Page 14: ...e TF 104 NC BUS BUS NA C Main Next floor 2Plus system with additional call repeater and 2nd door AC Lock release PRI SEC L1 L2 BUS CV2 CV1 12 S S BUS HZ HZ PB PA IMPORTANT For the configuration programming and intallation of 2Plus system see T2PlusML manual SW1 Sw1 Sw1 E of line T 7822VD SAR 2PLUS NC JP1 E of line BUS BUS NA C F N CALL REPEATER 220 Vac 1 8A max S S BUS HZ HZ PB PA Sw1 BUS E ofLine...

Page 15: ...0 V2Plus system with additional call repeater and stairs light activation JP1 SAR 2PLUS 220 Vac 1 8A max F N Stairs light activation NC NA C BUS BUS SAR 2PLUS NC JP1 BUS BUS NA C F N CALL REPEATER 220 Vac 1 8A max Configure End of line in the last monitor phone or SAR 2Plus SW2 SW2 R 120 IMPORTANT For the configuration programming and intallation of V2Plus system see TV2PlusML manual INSTALLATION ...

Page 16: ...k that the voltage and the current of the Lock release connected to the SAR 2Plus are correct see page 33 If voltage and current are correct replace the fuse with one of the same characteristics see page 33 The blown fuse must be replaced by and in the absence of electrical current The activation time of the Lock release is not the desired Check the proper adjustment of the potentiometer see page ...

Page 17: ...48 NOTAS NOTES ...

Page 18: ...NOTAS NOTES 49 ...

Page 19: ...50 NOTAS NOTES ...

Page 20: ...E 2004 108 CEE 93 68 CEE 2006 95 ECC 2004 108 ECC 93 68 ECC This product meets the essentials requirements of applicable European Directives regarding Electrical Safety Electromagnetic Compatibility and as amended for CE Marking NOTA El funcionamiento de este equipo está sujeto a las siguientes condiciones 1 Este dispositivo no puede provocar interferencias dañinas y 2 debe aceptar cualquier inter...

Reviews: