DESCRIPTION OF SAR-GB2 RELAY UNIT

4

Descrip

:

tion

RELAY UNIT TSAR-GB2

POWER IN-USE

BUS

BUS

.

.

SAR-GB2

C N.C

P AP

N.A

12+

CONTACTOS RELE /
RELAY CONTACTS

1,25 A 48 V ~ (Máx. 40w)

2 A 30 V      (Máx. 40w)

UNIDAD DE RELÉ
RELAY UNIT

a.

b.

c.

d.

12Vdc and “AP” output connector

.

Relay contact connector

.

Label.
JP

(do not use)

jumper

.

Status LED (power supply)

.

Status LED (active)

.

.

SW1 dip switch
DIN rail latch release.

e.

f.

g.
h.

a

d

c

e

b

g

f

h

The relay unit can be mounted onto a DIN rail
(4 elements) by applying slight pressure.
To remove the relay unit from the rail, use a flat
screwdriver and lever it off, as shown in the
drawing

.

Install the relay unit in a dry and protected location free from the risk of dripping or splashing water.

DIN 46277

Install the SAR-GB2 relay unit and SAR-12/24 together with the FA-GB2A power supply unit.

INSTALLATION

Detail of the installation of the relay unit:

POWER IN-USE

BUS

BUS

.

.

SAR-GB2

C N.C

P AP

N.A

12+

CONTACTOS RELE /
RELAY CONTACTS

1,25 A 48 V ~ (Máx. 40w)

2 A 30 V      (Máx. 40w)

UNIDAD DE RELÉ
RELAY UNIT

Summary of Contents for SAR-GB2

Page 1: ...MANUAL Code 50121952 T E SAR GB2 N REV 0117 RELAY UNIT SAR B G 2 POWER IN USE BUS BUS SAR GB2 C N C P AP N A 12 CONTACTOS RELE RELAY CONTACTS 1 25 A 48 V M x 40w 2 A 30 V M x 40w UNIDAD DE REL RELAY...

Page 2: ...of relay contacts shall not exceed from 2Ato 30 Vdc 1 25Ato 48 Vac Before connecting the system to the mains check the connections Always follow the instructions contained in this manual Introduc 2 t...

Page 3: ...ease 2 and with the panel that has been assigned through configuration in SAR GB2 during a call or communication process or It will be activated through the push button lock release 1 or lock release...

Page 4: ...g f h The relay unit can be mounted onto a DIN rail 4 elements by applying slight pressure To remove the relay unit from the rail use a flat screwdriver and lever it off as shown in the drawing Instal...

Page 5: ...and AP 8 Step Connect the power supply see step 4 9 Step Check that the operating mode is correct activating the light or lock release depending on the configuration 10 Note Repeat the procedure steps...

Page 6: ...upply to the SAR GB2 relay unit by inserting the relay unit Bus connector LED showing 2 the power supply status will turn on Step In the first 5 seconds after connecting the power supply to the relay...

Page 7: ...o the SAR GB2 relay unit by inserting the relay unit Bus connector LED showing 2 the power supply status will turn on Step In the first 5 seconds after connecting the power supply to the relay unit by...

Page 8: ...of the SAR 12 24 IMPORTANT For the description installation configuration and programming of the system see the corresponding manual Vac lock release TF 104 Main PRI SEC Golmar additional alternating...

Page 9: ...NOT S E 9 RELAY UNIT TSAR GB2...

Page 10: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...