GKP-2302 User Manual
142
2.
In the [AGC] item, select [1: OFF]. When [OFF] is selected here, the AGC calibration
finishes.
3.
Use the [Rmt Sense] item to set the Remote sensing function to on or off, if necessary.
4.
Close the window.
4.13
Using Autocal Function
The Autocal (Automatic Calibration) function calculates the ratio (calibration factor) of the
output voltage measured value (effective value) versus the output voltage setting value when
this function is turned on, and multiplies the gain of the output amplifier by the calculated
value, intending to match the output voltage with the setting value. The calculated calibratio n
factor is used as a fixed value until the Autocal function is turned off. Therefore, even when the
Autocal function is on, the output voltage fluctuation may occur if the load is fluctuated. When
the Autocal function is set to on, the icon
is displayed.
As the detected part of the output voltage calibrated by the Autocal function, either the sensing
input terminal (the Remote sensing function is on) or the output terminal (the Remote sensing