GKP-2302 User Manual
192
--------
Notes
----------------------------------------------------------------------------------------------------------------
The E mark does not mean it is faulty but indicates the protection operation was activated.
In some cases such as the protection operation was activated in a chain-reaction manner,
the E mark may appear on a normal power unit. A power unit is judged as faulty by
checking whether the error repeats or not after the power unit is restarted as described in
the step 2.
When the error message is "ID:54 Power Unit DCPS Undervoltage" or "ID:52 Power Unit
DCPS Error," the error is quite likely to be resolved after the power unit is restarted as
described in the step 2.
---------------------------------------------------------------------------------------------------------------------------------
7.1.4
Protection Operation Types
When the protection function is activated or an error is detected, the product applies one of the
following five types of protection operation and error message, according to the error level.
System Lock
The output turns off. No operations are accepted on the control panel. The panel says "System
Locked." To operate the product again, it is necessary to cycle the power of it.
Output Off
The output turns off. The panel says "Output OFF" and "Press Enter Key." When you press the
ENTER key, you will return to the previous window for further operations if the cause of the
error has been removed. Otherwise, the error message window will be displayed again.
When the [PU-ON] soft-key is displayed on the error message window, pressing the soft-key
opens the power unit energization setting window. If an error repeatedly occurs, you can
disable the energization of the power unit that has the error to continue to use the product with
the rest of the power units. For details, see
Message display only
The output state remains unchanged. The panel shows the error message window. Press the
ENTER key to return to the previous screen for further operations.
Limiting action
The output is limited. The panel shows the icon indicating the limiting action, without an error
message. In addition, the LIMIT LED illuminates on the front panel. The output turns off after a
given period according to the limiter setting. In this case, an error message appears after the
output off.
Icon display
The output state remains unchanged. The panel shows an icon instead of an error message. The
panel operation is available as usual.
Summary of Contents for GKP-2302
Page 15: ...1 1 OUTLINE 1 1 Overview 2 1 2 Features 2...
Page 28: ...GKP 2302 User Manual 14 Nothing is connected to the output terminal...
Page 60: ......
Page 186: ......
Page 187: ...173 5 DESCRIPTION OF SCREEN AND MENU 5 1 Screen Configuration 174 5 2 Menu Composition 177...
Page 195: ...181 6 REMOTE CONTROL 6 1 Communication Interface 182 6 2 Remote Local State Switching 188...
Page 216: ......
Page 222: ......