GKP-2302 User Manual
194
ID
Message
Protection
type
Cause or Necessary action
33
Line Overvoltage
System
Lock
The power input voltage is excessive.
Check if the power input is appropriate.
34
Line Undervoltage
System
Lock
The power input voltage is insufficient.
Check if the power input is appropriate.
35
Line Frequency Error
System
Lock
The power input frequency is abnormal.
Check if the power input is appropriate.
36
Communication Failure
PU
System
Lock
There is a communication error between
the firmware and the power unit. Cycle
the power. If it still occurs, contact the
seller (GW Instek or an authorized
distributor) from whom you purchased
the product.
37
Communication Failure
ME
System
Lock
There is a communication error between
the firmware and the output
measurement section. Cycle the power. If
it still occurs, contact the seller (GW
Instek or an authorized distributor) from
whom you purchased the product.
43
Mismatched Pw Unit
Versions
System
Lock
All power unit versions do not match.
44
Unsupported Pw Unit
Version
System
Lock
A power unit of unsupported version is
connected.
47
No Available Power
Unit
System
Lock
There is no power unit that can be started.
48
Output Overvoltage
Output Off
The output voltage is excessive. This may
occur at an abrupt change in the output
current due to the inductive load.
50
Output Overcurrent
[RMS]
Output Off
The output current RMS value is excessive
on a module in the power unit. This may
occur when the output terminal is
short-circuited.
51
Output Overcurrent
[Peak]
Output Off
The output current peak value is
excessive.
52
Power Unit DCPS Error Output Off
The DC power supply in the power unit is
abnormal, or see the notes in "
Operation procedure."
53
Power Unit DCPS
Overvoltage
Output Off
The voltage of the DC power supply in
the power unit is excessive. This may
occur when the power flows back from
the load.
54
Power Unit DCPS
Undervoltage
Output Off
The voltage of the DC power supply in
the power unit is insufficient, or see the
notes in "
, Operation procedure."
This may occur when the overload output
activated the protection function on the
DC power supply.
55
Overheat
Output Off
The temperature in the power unit is
abnormally high. Check if the ambient
temperature is appropriate. Check the
filters for clogging. For filter cleaning, see
Table 8-2 Error Message List (Continued)
Summary of Contents for GKP-2302
Page 15: ...1 1 OUTLINE 1 1 Overview 2 1 2 Features 2...
Page 28: ...GKP 2302 User Manual 14 Nothing is connected to the output terminal...
Page 60: ......
Page 186: ......
Page 187: ...173 5 DESCRIPTION OF SCREEN AND MENU 5 1 Screen Configuration 174 5 2 Menu Composition 177...
Page 195: ...181 6 REMOTE CONTROL 6 1 Communication Interface 182 6 2 Remote Local State Switching 188...
Page 216: ......
Page 222: ......