BLOWER PERFORMANCE SPECIFICATIONS
18
GCVM96 / ACVM96
High (Single) Stage Cooling Speed Charts
High- or Single-Stage Cooling Speeds
Cooling
Speed Tap
Adjust
Tap
CFM *
Cooling
Speed Tap
Adjust
Tap
CFM *
Cooling
Speed Tap
Adjust
Tap
CFM *
Minus(-)
594
Minus(-)
810
Minus(-)
702
Normal
660
Normal
900
Normal
780
Plus (+)
726
Plus (+)
990
Plus (+)
858
Minus(-)
774
Minus(-)
990
Minus(-)
963
Normal
860
Normal
1100
Normal
1070
Plus (+)
946
Plus (+)
1210
Plus (+)
1177
Minus(-)
1035
Minus(-)
1287
Minus(-)
1242
Normal
1150
Normal
1430
Normal
1380
Plus (+)
1265
Plus (+)
1573
Plus (+)
1518
Minus(-)
1323
Minus(-)
1692
Minus(-)
1602
Normal
1470
Normal
1880
Normal
1780
Plus (+)
1617
Plus (+)
2068
Plus (+)
1958
* @ .1" - .8" w.c . ESP
No tes:
All f urnac es ship as high speed f or c ooling. I nstaller must adjust blower s peed as needed.
F or most jobs , about 400 CFM per ton when c ooling is des irable.
Do not operat e above .5” w. c. ESP in heating mode. O perating CFM between . 5” and . 8” w.c. is t abulated for cooling purposes only.
GCVM960604CX
ACVM960604CX
A
B
D
GCVM960805DX
ACVM960805DX
D
GCVM961005DX
ACVM961005DX
A
B
C
D
A
B
C
C