ASPF THERMOSTAT CONNECTIONS

The following composite wiring diagrams detail various configurations in which the ASPF air handlers can be used.  Ex-
amples include single-stage cooling and heat pump with single or two-stage electric heating.  All these configurations can be
applied with convenient connections to outdoor thermostat applications.

The following sections will be detailed:

Single-Stage Cooling (GMC Thermostat Part #CHT18-60 or equivalent.)

Heat Pump (GMC Thermostat Part #18-60 or equivalent)

Each diagram details the connections between room thermostat and ASPF air handlers, and the connections between the
ASPF air handlers and the Condensing Unit (or Heat Pump) with optional connections to Outdoor Thermostats.  For each
configuration, refer to the explanation of the proper jumper(s) to remove for the corresponding blower speed that will result
in the programmed ECM™ motor.

IMPORTANT: WHEN MATCHING THE ASPF AIR HANDLERS TO A SINGLE SPEED COOL-
ING OR HEAT PUMP UNIT, REMEMBER TO CONNECT “Y” FROM THE THERMOSTAT TO
THE “Y2” ON THE LOW VOLTAGE TERMINAL BOARD.

An equivalent thermostat can be used in place of the Goodman thermostat part number.  The GMC thermostats that listed
are mercury type thermostats.

HIGH VOLTAGE!

 DISCONNECT ALL POWER BEFORE SERVICING.

MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

COOLING UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW

G

R

C

W1

Y

W

W2

Y2

Y1

O

G

R

TB

YL

BL

TO CONDENSING UNIT
24V CONNECTION

BL

YL

YL

WH

GR

RD

#18 GA. 4 WIRES WITH COOLING
3 WIRES WITHOUT

NOTES:

1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE

FIRST TO CLOSE AND THE LAST TO OPEN.

2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT

USED.

3) REMOVE WIRE WHEN USING OUTDOOR THERMO-

STAT.

NOMENCLATURE:

OT - OUTDOOR THERMOSTAT (OPTIONAL)

EHR - EMERGENCY HEAT RELAY (OPTIONAL)

COLOR CODES

RD - RED

YL - YELLOW

BL - BLUE

BR - BROWN

OR - ORANGE

WH - WHITE

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

Summary of Contents for ADPF

Page 1: ...LING PERSONNEL Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your respon...

Page 2: ...Canadian Electric Code CSA C22 1 uninterrupted unbroken When installing or servicing this equipment safety clothing including hand and eye protection is strongly recommended If installing in an area t...

Page 3: ...he Prod uct Registration page Product limited warranty certificates for models currently in production can be viewed at www goodmanmfg com or www amana hac com If your model is not currently in pro du...

Page 4: ...e con structed in a manner that limits restrictions and maintains suitable air velocity Ductwork is to be sealed to the unit in a manner that will prevent leakage Return Ductwork DO NOT TERMINATE THE...

Page 5: ...g the ground lug in the unit control box to the building electrical service panel Other methods of grounding are permitted if performed in accordance with the National Electric Code NEC American Natio...

Page 6: ...n denser or heat pump The 24V control voltage connects the air handler to the room thermostat and condenser Low volt age wiring is to be copper conductors A minimum of 18AWG must be used for installat...

Page 7: ...r handler in its final location To prevent the evaporator coil pan from sweat ing the DPI accessory insulation kit is to be used when per forming this conversion NOTE The DPI kit is not supplied with...

Page 8: ...left side access panel and slide out the evaporator coil and horizontal drain pan 4 Remove the gasket from the horizontal pan drain con nections 5 Remove the oval shaped plastic plug from the left sid...

Page 9: ...EQUIRED AT TRAP Drain Connection 2 MIN Figure 7 Use of a condensate removal pump is permitted when nec essary This condensate pump should have provisions for shutting off the control voltage should a...

Page 10: ...Assumes dry coil with filter in place SCFM correction for wet coil 4 208V 240V 0 1 0 2 0 3 0 4 0 5 High 1 155 1 090 1 025 950 895 ADPF18241 16 Med 940 890 860 815 755 Low 695 665 650 610 550 High 1 7...

Page 11: ...ge Return air is not obtained from any areas where there may be objectionable odors flammable vapors or prod ucts of combustion such as carbon monoxide CO which may cause serious personal injury or de...

Page 12: ...STAT W Y G R 18 GA 4 WIRES WITH COOLING 3 WIRES WITHOUT R G W Y TO CONDENSING UNIT 24V CONNECTIONS 18 GA 2 WIRES BLUE WHITE GREEN RED CONTACTOR COIL AT AR UNIT Figure 8 Low Voltage Wiring Diagram for...

Page 13: ...STAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AT AR UNIT R Y O W BL 18 GA 5 WIRE 18 GA 7 WIRE NOTE R G BR W BL R R I B 18 GA 6 WIRE NEEDED WHEN OT IS USED R 18 GA 7 WIRE NEEDED WHEN TWO OT S ARE...

Page 14: ...HEN MATCHING THE ASPF AIR HANDLERS TO A SINGLE SPEED COOL ING OR HEAT PUMP UNIT REMEMBER TO CONNECT Y FROM THE THERMOSTAT TO THE Y2 ON THE LOW VOLTAGE TERMINAL BOARD An equivalent thermostat can be us...

Page 15: ...B YL BL CONDENSING UNIT 24V CONNECTION BL YL GR RD 18 GA 5 WIRES WITH COOLING 4 WIRES WITHOUT WH YL BR BR BR YL G C R HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW C W1 W2 Y2 Y1 O G R TB 1...

Page 16: ...IT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE C W1 W2 Y2 Y1 O G R TB 18 GA 7 WIRE O Y C W2 R Y O W2 E RD GR BL OR YL YL BL OR WH BR WH BL WH WH RD BR RD WH GR YL OR OR RD OR NOTES 1 OUTDOOR THERMOSTAT...

Page 17: ...R A L G H E A T K I T M O T O R The Electronic Blower Time Delay Relay provides power to the blower motor with a delay of 7 seconds after 24VAC is applied to G After 24VAC is removed from G the blower...

Page 18: ...18 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 19: ...19 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 20: ...20 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 2004 2010 Goodman Manufacturing Company L P...

Reviews: