background image

3

To prevent the risk of property damage, personal 
injury, or death, do not store combustible materials or 
use gasoline or other flammable liquids or vapors in 
the vicinity of this unit.

 

 
 
 
 
 
 
 
 

 

 

 

CARBON MONOXIDE POISONING HAZARD  

-

 

 

Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas

Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions.  If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.

This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area.  Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.

CO can cause serious illness including permanent brain damage or death.

B10259-216

Important Note to the Owner regarding Product
Warranty

Your warranty certificate is supplied as a separate document
with the unit installed by your contractor. Read the limited
warranty certificate carefully to determine what is and is not
covered and keep the warranty certificate in a safe place. If
you are unable to locate the warranty certificate please con-
tact your installing contractor or contact customer service
(877-254-4729) to obtain a copy.

To receive the 10 Year Parts Limited Warranty, online regis-
tration must be completed within 60 days of installation.
Online registration is not required in California or Quebec.

To register your Goodman

®

 brand unit, go to

www.goodmanmfg.com.  Click on the word “Warranty” lo-
cated on the left side of the home page.  Next, click on the
word “Product Registration” located on the left side of the
Warranty page and complete the forms in the manner indi-
cated on the Product Registration page.

To register your Amana

®

 brand unit, go to www.amana-

hac.com.  Click on the word “Warranty” located on the top
right of the home page.  Next, click on the word “Product
Registration” located on the left side of the Warranty page
and complete the forms in the manner indicated on the Prod-
uct Registration page.

Product limited warranty certificates for models currently in
production can be viewed at www.goodmanmfg.com or
www.amana-hac.com.  If your model is not currently in pro-
duction or does not appear on the website, please contact
your installing contractor or contact customer service (877-
254-4729) to obtain a copy of your warranty certificate.

Each product overview page contains a Product Warranty
link; by clicking on it you will be able to view the limited war-
ranty coverage for that specific product. To view warranty
registration information, click on the Product Warranty text
on the left navigation panel on the home page of each web-
site. The Online Product Registration pages are located in
this same section.

Keep this literature in a safe place for future reference.

Shipping Inspection

Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and sub-
sequent investigation is the responsibility of the carrier.  Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distribu-
tor or manufacturer will not accept claims from dealers for
transportation damage or installation of incorrectly shipped
units.

Codes & Regulations

This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibil-
ity of the installer.  The manufacturer assumes no responsi-
bility for equipment installed in violation of any codes or regu-
lations.

The United States Environmental Protection Agency
(EPA) has issued various regulations regarding the in-
troduction and disposal of refrigerants. Failure to follow
these regulations may harm the environment and can
lead to the imposition of substantial fines. 

Should you

have any questions please contact the local office of the EPA.

Replacement Parts

When reporting shortages or damages, or ordering repair
parts, give the complete product model and serial numbers
as stamped on the product.  Replacement parts for this prod-
uct  are available through your contractor or local distributor.
For the location of your nearest distributor consult the white
business pages, the yellow page section of the local tele-
phone book or contact:

SERVICE PARTS DEPARTMENT

GOODMAN MANUFACTURING COMPANY, L.P.

5151 SAN FELIPE, SUITE 500

HOUSTON, TEXAS 77056

(713) 861 – 2500

If replacing an air handler, the system must be manufacturer
approved and Air-Conditioning, Heating, and Refrigeration
Institute (AHRI) matched.  

NOTE: 

Installation of unmatched

systems is strongly discouraged.

Summary of Contents for ADPF

Page 1: ...LING PERSONNEL Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your respon...

Page 2: ...Canadian Electric Code CSA C22 1 uninterrupted unbroken When installing or servicing this equipment safety clothing including hand and eye protection is strongly recommended If installing in an area t...

Page 3: ...he Prod uct Registration page Product limited warranty certificates for models currently in production can be viewed at www goodmanmfg com or www amana hac com If your model is not currently in pro du...

Page 4: ...e con structed in a manner that limits restrictions and maintains suitable air velocity Ductwork is to be sealed to the unit in a manner that will prevent leakage Return Ductwork DO NOT TERMINATE THE...

Page 5: ...g the ground lug in the unit control box to the building electrical service panel Other methods of grounding are permitted if performed in accordance with the National Electric Code NEC American Natio...

Page 6: ...n denser or heat pump The 24V control voltage connects the air handler to the room thermostat and condenser Low volt age wiring is to be copper conductors A minimum of 18AWG must be used for installat...

Page 7: ...r handler in its final location To prevent the evaporator coil pan from sweat ing the DPI accessory insulation kit is to be used when per forming this conversion NOTE The DPI kit is not supplied with...

Page 8: ...left side access panel and slide out the evaporator coil and horizontal drain pan 4 Remove the gasket from the horizontal pan drain con nections 5 Remove the oval shaped plastic plug from the left sid...

Page 9: ...EQUIRED AT TRAP Drain Connection 2 MIN Figure 7 Use of a condensate removal pump is permitted when nec essary This condensate pump should have provisions for shutting off the control voltage should a...

Page 10: ...Assumes dry coil with filter in place SCFM correction for wet coil 4 208V 240V 0 1 0 2 0 3 0 4 0 5 High 1 155 1 090 1 025 950 895 ADPF18241 16 Med 940 890 860 815 755 Low 695 665 650 610 550 High 1 7...

Page 11: ...ge Return air is not obtained from any areas where there may be objectionable odors flammable vapors or prod ucts of combustion such as carbon monoxide CO which may cause serious personal injury or de...

Page 12: ...STAT W Y G R 18 GA 4 WIRES WITH COOLING 3 WIRES WITHOUT R G W Y TO CONDENSING UNIT 24V CONNECTIONS 18 GA 2 WIRES BLUE WHITE GREEN RED CONTACTOR COIL AT AR UNIT Figure 8 Low Voltage Wiring Diagram for...

Page 13: ...STAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AT AR UNIT R Y O W BL 18 GA 5 WIRE 18 GA 7 WIRE NOTE R G BR W BL R R I B 18 GA 6 WIRE NEEDED WHEN OT IS USED R 18 GA 7 WIRE NEEDED WHEN TWO OT S ARE...

Page 14: ...HEN MATCHING THE ASPF AIR HANDLERS TO A SINGLE SPEED COOL ING OR HEAT PUMP UNIT REMEMBER TO CONNECT Y FROM THE THERMOSTAT TO THE Y2 ON THE LOW VOLTAGE TERMINAL BOARD An equivalent thermostat can be us...

Page 15: ...B YL BL CONDENSING UNIT 24V CONNECTION BL YL GR RD 18 GA 5 WIRES WITH COOLING 4 WIRES WITHOUT WH YL BR BR BR YL G C R HEAT PUMP UNIT WITH OPTIONAL HEAT KITS OF 10 kW AND BELOW C W1 W2 Y2 Y1 O G R TB 1...

Page 16: ...IT WITH OPTIONAL HEAT KITS OF 15 kW AND ABOVE C W1 W2 Y2 Y1 O G R TB 18 GA 7 WIRE O Y C W2 R Y O W2 E RD GR BL OR YL YL BL OR WH BR WH BL WH WH RD BR RD WH GR YL OR OR RD OR NOTES 1 OUTDOOR THERMOSTAT...

Page 17: ...R A L G H E A T K I T M O T O R The Electronic Blower Time Delay Relay provides power to the blower motor with a delay of 7 seconds after 24VAC is applied to G After 24VAC is removed from G the blower...

Page 18: ...18 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 19: ...19 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 20: ...20 Goodman Manufacturing Company L P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com 2004 2010 Goodman Manufacturing Company L P...