BLOWER PERFORMANCE DATA
20
ARUF
Note: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)
0.1"
0.2"
0.3"
0.4"
0.5"
High
1155
1090
1025
950
895
ARUF172916
M ed.
940
890
860
815
755
Low
695
665
650
610
550
High
1155
1090
1025
950
895
ARUF182416
M ed.
940
890
860
815
755
Low
695
665
650
610
550
High
1135
1085
1025
965
915
ARUF193116
M ed.
860
825
780
750
680
Low
600
570
545
500
465
High
1385
1315
1240
1155
1065
ARUF303016
M ed.
1340
1290
1230
1140
1050
Low
1075
1030
980
910
840
High
1310
1240
1155
1090
1020
ARUF363616
M ed.
1270
1210
1140
1075
980
Low
1045
1005
955
885
805
High
1700
1660
1625
1545
1505
ARUF364216
M ed.
1500
1440
1400
1350
1345
Low
1330
1300
1250
1230
1220
High
2065
2000
1925
1860
1780
ARUF374316
M ed.
1685
1635
1550
1470
1410
Low
1490
1425
1345
1280
1205
High
2150
2120
2070
2000
1940
ARUF486016
M ed.
1940
1930
1905
1860
1790
Low
1610
1600
1590
1575
1550
High
2150
2105
2040
1970
1880
ARUF496116
M ed.
1960
1935
1895
1825
1750
Low
1670
1625
1585
1525
1455
CFM deliverd against External Static Pressure
M odel
Speed