background image

14

WIRING DIAGRAMS

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

 AL

L

 POW

E

R BEF

O

RE

 SERVICI

NG OR IN

S

T

A

L

L

IN

G

 T

H

IS

UNIT

 M

U

L

T

IPL

E

 PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

 F

A

IL

URE 

T

O

DO SO 

M

A

Y CAUS

E PROP

ERT

Y

 DAM

AG

E, 

PERSONAL

 I

N

J

U

R

Y

 OR DE

A

T

H

.

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

GKS9*****X**

R

YL YELLOW
OR ORANGE

PU PURPLE
GN GREEN
BK BLACK

BR BROWN
WH WHITE

BL BLUE
GY GRAY
RD RED

COLOR CODES:

LOW

 

VOLTAGE

 

(24V)

LOW

 

VOLTAGE

 

FIELD

HI

 

VOLTAGE

 

(115V)

HI

 

VOLTAGE

 

FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

0140F00236 REV. D

 

OR

 

(MED

 

LOW)

 

BL

 

(MED)

 

RD

 

(LOW)

GAS

 

VALVE

C2

C

G

W

       

INTERNAL

 

TO

INTEGRATED

 

CONTROL

JUNCTION

EQUIPMENT

 

GND

FIELD

 

GND

DIAGNOSTIC
LED

2

 

CIRCUIT

CONNECTOR

HOT
SURFACE
IGNITER

 

OVERCURRENT

PROT.

 

DEVICE

IGNITER

TH

 

(3)

INTEGRATED
CONTROL MODULE

JUNCTION

 

BOX

LINE-H

XFMR-H

IN
T

E

G

R

A

T

E

D

 C
O

N

T

R

O

M

O

D

U

L

E

IN

T

E

GR

A

T

E

D

 CO

NT
R

O

M

O

D

U

L

E

GND

DISCONNECT

L

N

OVERCURRENT

 

PROTECTION

 

DEVICE

RD

BL

BK

4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS. UNUSED

BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST 105

TERMINAL

SWITCH

 

(PRESS.)

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

PK

 

PINK

115

 

VAC

 

HOT

 

AND

 

PARK

 

TERMINALS

LINE-H

FLAME
SENSOR

BK

PLUG

 

CONNECTION

FIELD

 

SPLICE

SWITCH

 

(TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

GR

GND

115 VAC

24 VAC

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN

DOOR OPEN)

DOOR
SWITCH

BK

GND

L

N

WH

JUNCTION

 

BOX

1

OR

ID

 

BLOWER

PRESSURE
SWITCH

HEAT-H

GND

WH

RD

WH

GND

BURNER

 

COMPARTMENT

BLOWER

 

COMPARTMENT

NOTE

 

4

SEE

N
O

COOL-H

 

BK

 

(HI)

BR

BR

CAPACITOR

YL

WH

BL

PU

 

RD

OR

PK

BK

WH

WH

BLOWER

INDUCED

 

DRAFT

MANUAL

 

RESET

AUXILIARY

 

LIMIT

IN

 

UPFLOW

BLOWER

 

DECK

C

FS

HE

AT

-H

CO

OL

IGNITER

HOT

 

SURFACE

IND

IGN

BLWR

CIRCULATOR

BLWR

ID

FLAME

 

SENSOR

115

 

VAC

TRANSFORMER

40

 

VA

24

 

VAC

GND

RO1

 

(5)

RO2

 

(11)

HLO

 

(1)

HLI

 

(7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

 

PK

PK

WH

11

5

 V

A

C N

E

UTRA

L

BK

BK

BK

GY

2

4

V

 T

H

ER
MO

ST
A

T

 CO
NN

E

C

TI

O

N

S

MICRO

TO

C

G

Y

W

R

2

WH

OR

BL

YL

OR

PK

RD

OR

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

BL

GY

GR

1

2

3

12

11

10

9

8

7

6

5

4

°C. USE COPPER CONDUCTORS ONLY.

24 VAC

HUMIDIFIER

24

 

VAC

HUMIDIFIER

HUMIDIFIER

PSO

 

(4)

MV(12)

PS

 

(10)

C

NO

ID BLOWER
PRESSURE

SWITCH

0

C

6

5

4

3

2

1

OFF

               

=

 

CONTROL

 

FAILURE

STEADY

 

ON

 

=

 

NORMAL

 

OPERATION

1 FLASH

 

      

=

2 FLASHES

  

=

 

PRESSURE

 

SWITCH

 

STUCK

 

CLOSED

3 FLASHES

  

=

 

PRESSURE

 

SWITCH

 

STUCK

 

OPEN

4 FLASHES

 

 

=

 

OPEN

 

HIGH

 

LIMIT

5 FLASHES

  

=

 

FLAME

 

SENSE

 

WITHOUT

 

GAS

 

VALVE

6 FLASHES

  

=

CONTINUOUS/RAPID

 

FLASHES

 

=

 

REVERSED

 

115

 

VAC

 

POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

MI

GY

GY

M1

GAS

VALVE

C2

TO

 

115VAC/

 

1 Ø

 

/60

 

HZ

 

POWER

 

SUPPLY WITH

PU

Y

BR

GY

BR

LI

N

E

 NE

UT
R

A

L

S

NO

C

OPTIONAL

 

FRONT

 

COVER

PRESSURE

 

SWITCH

C

N
O

OPTIONAL

 

FRONT

 

COVER

PRESSURE

 

SWITCH

Summary of Contents for GKS9

Page 1: ...ocedures or services performed by an unqualified person Refer to Service Manual RS6610004 for installation operation and troubleshooting information All safety information must be followed as provided...

Page 2: ...0 Btuh 070 70 000 Btuh 090 90 000 Btuh 115 115 000 Btuh N Natural Gas X Low NOx WARNING WARNING HIGH VOLTAGE Disconnect ALL power before servicing or installing this unit Multiple power sources may be...

Page 3: ...nd disposal of refrigerants introduced into this unit Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jur...

Page 4: ...quipped with an electronic ignition device used to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not...

Page 5: ...uced Draft Blower 16 Electrical Connection Inlets Alternate 17 Coil Front Cover Drain Port 18 Drain Line Penetrations 19 Blower Door Interlock Switch 20 24 Volt Thermostat Connections 21 Integrated Co...

Page 6: ...1 8 16 19 3 8 12 15 16 15 15 16 20 7 16 LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE SIDE CUT OUT LEFT SIDE VIEW SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDA...

Page 7: ...FIRING TYPICAL SEA LEVEL DATA MODEL TRIP POINT COIL COVER PRESSURE SWITCH COIL COVER PRESSURE SWITCH PART TRIP POINT ID BLOWER PRESSURE SWITCH ID BLOWER PRESSURE SWITCH PART TRIP POINT COIL COVER PRES...

Page 8: ...1 GKS91155DX 1 T O D PRIMARY LIMIT Part Number 10123514 or 10123533 Open Setting F 200 GKS90453BX 1 GKS90703BX 2 GKS90704CX 2 GKS90904CX 2 GKS90905DX 2 GKS91155DX 2 ROLLOUT LIMIT SWITCHES Part Number...

Page 9: ...e in both cased and uncased models with the option of a field installed TXV expansion device These 90 furnaces match up with the existing Amana brand coils as shown in the chart below C A P F 1824 A 6...

Page 10: ...lter Area in2 Based on a 300 ft min filter face velocity Minimum filter area dictated by heating airflow requirement Permanent Minimum Filter Area in2 Based on 600 ft min filter face velocity Minimum...

Page 11: ...ordance with all national and or local electrical codes Use copper wire only MODEL GKS9 0453BX GKS9 0703BX GKS9 0704CX GKS9 0904CX GKS9 0905DX GKS9 1155DX Btuh Input US 46 000 69 000 69 000 92 000 92...

Page 12: ...84 38 817 741 611 LOW 1 5 757 44 753 44 734 45 704 47 674 49 620 524 438 HIGH 3 0 1449 36 1409 37 1326 39 1273 41 1201 43 1194 1136 1018 GKS90703BX MED 2 5 1192 43 1172 44 1141 45 1094 47 1046 49 973...

Page 13: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Page 14: ...105 TERMINAL SWITCH PRESS 5 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES PK PINK 115 VAC HOT AND PARK TERMINALS LINE H FLAME SENSOR BK PLUG CONNECTION FIELD SPLICE SWITCH TEM...

Reviews: