background image

14

WIRING DIAGRAMS

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

 AL

L

 POW

E

R BEF

O

RE

 SERVICI

NG OR IN

S

T

A

L

L

IN

G

 T

H

IS

UNIT

 M

U

L

T

IPL

E

 PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

 F

A

IL

URE 

T

O

DO

 SO

 M

A

Y CAUS

E

 PRO

P

ERTY DAM

A

G

E

PERSO

NAL

 I

N

J

U

R

Y

 O

R

 DE

A

T

H

.

R

YL

 

YELLOW

OR

 

ORANGE

PU

 

PURPLE

GN

 

GREEN

BK

 

BLACK

BR

 

BROWN

WH

 

WHITE

BL

 

BLUE

GY

 

GRAY

RD

 

RED

COLOR

 

CODES:

LOW

 

VOLTAGE

 

(24V)

LOW

 

VOLTAGE

 

FIELD

HI

 

VOLTAGE

 

(115V)

HI

 

VOLTAGE

 

FIELD

NOTES:

1.

 

SET

 

HEAT

 

ANTICIPATOR

 

ON

 

ROOM

 

THERMOSTAT

 

AT

 

0.7

 

AMPS.

2.

 

MANUFACTURER'S

 

SPECIFIED

 

REPLACEMENT

 

PARTS

 

MUST

 

BE

 

USED

 

WHEN

 

SERVICING.

0140F00592

 

REV.

 

A

 

OR

 

(MED

 

LOW)

 

BL

 

(MED)

 

RD

 

(LOW)

GAS

 

VALVE

C

PM

C

G

W

       

INTERNAL

 

TO

INTEGRATED

 

CONTROL

JUNCTION

EQUIPMENT GND

FIELD GND

DIAGNOSTIC
LED

2

 

CIRCUIT

CONNECTOR

HOT
SURFACE
IGNITER

 

OVERCURRENT

PROT.

 

DEVICE

IGNITER

TH

 

(3)

INTEGRATED
CONTROL MODULE

JUNCTION

 

BOX

LINE-H

XFMR-H

INT

E

GRA

T

ED CONTROL

 MODULE

IN

TEGRA

T

E

D

 CONTROL 

MODULE

GND

DISCONNECT

L

N

OVERCURRENT

 

PROTECTION

 

DEVICE

BR

GY

RD

BL

BK

4.

 

IF

 

HEATING

 

AND

 

COOLING

 

BLOWER

 

SPEEDS

 

ARE

 

NOT

 

THE

 

SAME,

 

DISCARD

 

JUMPER

 

BEFORE

 

CONNECTING

 

BLOWER

 

LEADS. UNUSED

 

  

BLOWER

 

LEADS

 

MUST

 

BE

 

PLACED

 

ON

 

"PARK"

 

TERMINALS

 

OF

 

INTEGRATED

 

CONTROL

 

OR

 

TAPED.

3.

 

IF

 

ANY

 

OF

 

THE

 

ORIGINAL

 

WIRE

 

AS

 

SUPPLIED

 

WITH

 

THE

 

FURNACE

 

MUST

 

BE

 

REPLACED,

 

IT

 

MUST

 

BE

 

REPLACED

 

WITH

 

WIRING MATERIAL

HAVING

 

A

 

TEMPERATURE

 

RATING

 

OF

 

AT

 

LEAST

 

105

TERMINAL

SWITCH

 

(PRESS.)

5.

 

UNIT

 

MUST

 

BE

 

PERMANENTLY

 

GROUNDED

 

AND

 

CONFORM

 

TO

 

N.E.C.

 

AND

 

LOCAL

 

CODES.

PK

 

PINK

115

 

VAC

 

HOT

 

AND

 

PARK

 

TERMINALS

LINE-H

FLAME
SENSOR

FRONT

 

COVER

PRESSURE

 

SWITCH

N
O

C

GY

BK

PLUG

 

CONNECTION

FIELD

 

SPLICE

SWITCH

 

(TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

GR

GND

115 VAC

24 VAC

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN

DOOR OPEN)

DOOR
SWITCH

BK

GND

L

N

WH

JUNCTION

 

BOX

1

 

OR

ID

 

BLOWER

PRESSURE
SWITCH

HEAT-H

GND

WH

RD

WH

GND

BURNER

 

COMPARTMENT

BLOWER

 

COMPARTMENT

NOTE

 

4

SEE

N
O

COOL-H

 

BK

 

(HI)

BR

BR

CAPACITOR

YL

WH

YL

BL

PU

 

RD

OR

PK

BK

WH

WH

BLOWER

INDUCED

 

DRAFT

MANUAL

 

RESET

AUXILIARY

 

LIMITS

(1)

 

IN

 

UPFLOW

      

BLOW ER

 

DECK

(2)

 

IN

 

C'FLOW

  

    

BLOW ER

 

HOUSING

C

FS

HI

HE

AT

-H

LO

HE

AT

-H

IGNITER

HOT

 

SURFACE

IND

IGN

EAC-H

AIR

 

CLEANER

ELECTRONIC

BLWR

CIRCULATOR

BLWR

ID

FLAME

 

SENSOR

115

 

VAC

TRANSFORMER

40

 

VA

24

 

VAC

GND

RO1

 

(5)

RO2

 

(11)

HLO

 

(1)

HLI

 

(7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

 

PK

PK

GY

WH

11

5

 V

A

C

 N
E

UT
RA
L

BK

BK

GY

24V

 THERMOST

A

T

 CONNECTI

O

NS

MICRO

TO

C

G

Y

W

R

2

WH

OR

BL

YL

OR

OR

GY

PK

RD

OR

GY

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

GY

OR

GR

BR

1

2

3

12

11

10

9

8

7

6

5

4

°C.

 

USE

 

COPPER

 

CONDUCTORS

 

ONLY.

24 VAC

HUMIDIFIER

24

 

VAC

HUMIDIFIER

HUMIDIFIER

PSO

 

(4)

MVL(2)

PS

 

(10)

C

NO

C

NO

FRONT COVER
PRESSURE

 

SWITCH

ID BLOWER
PRESSURE

SWITCH

0

C

7

6

5

4

3

2

1

OFF

               

=

 

CONTROL

 

FAILURE

 

  

STEADY

 

ON

 

=

 

NORMAL

 

OPERATION

  

 

1

 

FLASH

  

     

=

   

2

 

FLASHES

  

=

 

PRESSURE

 

SWITCH

 

STUCK

 

CLOSED

   

3

 

FLASHES

  

=

 

PRESSURE

 

SWITCH

 

STUCK

 

OPEN

  

 

4

 

FLASHES

  

=

 

OPEN

 

HIGH

 

LIMIT

   

5

 

FLASHES

  

=

 

FLAME

 

SENSE

 

WITHOUT

 

GAS

 

VALVE

   

7

 

FLASHES

  

=

 

LOW

 

FLAME

 

SIGNAL

  

 

6

 

FLASHES

  

=

   

CONTINUOUS/RAPID

 

FLASHES

 

=

 

REVERSED

 

115

 

VAC

 

POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

ON

OFF

2ND
STAGE
DELAY

MODE

HEAT
OFF
DELAY

FS

1

2

3

HI

OR

OR

PM

GAS

VALVE

C

HI

MVH (12)

FACTORY

 

SETTINGS

SHOWN

*

*

*

*

SEE
NOTE 6

COOL-H

TO

 

115VAC/

 

 

/60

 

HZ

 

POWER

 

SUPPLY WITH

PU

Y

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS

 

WHILE IN

    STANDBY

 

(NO THERMOSTAT INPUTS)

BK

LIN

E

 NEUT

RALS

8

   

8

 

FLASHES

 

 

=

 

CHECK

 

IGNITER

 

OR

 

IMPROPER

 

GROUNDING

GMH95[0453,0704,0905]*XAB

GMH95[0703,0904,1155]*XAC

Summary of Contents for GMH95

Page 1: ...og for part number information Model numbers listed on page 3 Copyright 2007 2009 2010 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL...

Page 2: ...onnect ALL power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death Installation and repair of this unit...

Page 3: ...o follow these regulations may harm the environment and can lead to the imposition of substantial fines These regulations may vary by jurisdiction Should questions arise contact your local EPA office...

Page 4: ...rts in Service Instructions General Operation The GMH95 furnaces are equipped with an electronic igni tion device used to light the burners and an induced draft blower to exhaust combustion products A...

Page 5: ...as Line Entrance 14 Flue Pipe Connection Alternate 15 Rubber Elbow 16 Induced Draft Blower 17 Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20...

Page 6: ...SIDE CUT OUT LOW VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES STANDARD GAS SUPPLY HOLE DRAIN TRAP 19 3 4 AIR INTAKE PIPE 2 PVC LEFT SIDE DRAIN LINE HOLES 1 5 8 RIGHT SIDE VIEW CONDENSATE DRAIN...

Page 7: ...5 0 10 0 10 20197308 1 35 0130F00110 TBD TBD TBD GMH950905DXA 1 30 1 10 0 52 0 37 0 37 20197312 1 10 0130F00000P TBD TBD TBD GMH951155DXA 1 30 1 10 0 75 0 60 0 60 20197310 1 10 0130F00000P TBD TBD TBD...

Page 8: ...LIMIT Part Number 10123514 or 10123533 10123517 Open Setting F 200 210 GMH950453BXA 1 GMH950703BXA 2 GMH950704CXA 2 GMH950904CXA 2 GMH950905CXA 2 GMH950905DXA 2 GMH951155DXA 2 ROLLOUT LIMIT SWITCHES...

Page 9: ...C D heights have an insulated Z bracket for use with one size smaller furnace All proper coil combinations are subject to being ARI rated with a matched outdoor unit C A P F 1824 A 6 A PRODUCT TYPE C...

Page 10: ...filter face velocity Minimum filter area dictated by heating airflow requirement Cabinet Width in Nominal Filter Size in Approx Flow Area in 2 Cabinet Width in Nominal Filter Size in Approx Flow Area...

Page 11: ...MH95 0703BXA GMH95 0704CXA GMH95 0904CXA GMH95 0905CXA GMH95 0905DXA GMH95 1155DXA Btuh Input US 46 000 69 000 69 000 92 000 92 000 92 000 115 000 Output US 44 400 66 400 66 900 89 000 88 400 88 400 1...

Page 12: ...57 973 904 793 MED H I MED LO 2 0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1 5 750 79 730 81 714 83 692 86 657 90 620 570 502 H IGH 4 0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 127...

Page 13: ...0 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULA...

Page 14: ...FIELD SPLICE SWITCH TEMP OR 24V THERMOSTAT CONNECTIONS GR GND 115 VAC 24 VAC BLOWER COMPARTMENT DOOR SWITCH OPEN WHEN DOOR OPEN DOOR SWITCH BK GND L N WH JUNCTION BOX 1 OR ID BLOWER PRESSURE SWITCH H...

Page 15: ...ITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD O...

Page 16: ...COMPARTMENT DOORSWITCH OPENWHEN DOOROPEN DOOR SWITCH WARNING DISCONNECTPOWERBEFORE SERVICING WIRINGTOUNITMUSTBE PROPERLYPOLARIZEDANDGROUNDED BK GND DISCONNECT L N WH JUNCTION BOX 1 OR IDBLOWER PRESSU...