37
GMS95 WIRING DIAGRAM
GMS95 WIRING DIAGRAM
GMS95 WIRING DIAGRAM
GMS95 WIRING DIAGRAM
GMS95 WIRING DIAGRAM
©
2005-2006 Goodman Manufacturing Company, L.P.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
TO 115VAC/ 1
Ø /60 HZ POWER SUPPLY WITH
120
*
180
60
90
PIN JUMPER
AS SHIPPED FROM FACTORY
*
*
ON
DIP SWITCHES
OFF
OFF
OFF
ON
ON
OFF
ON
OR
180
120
90
60
(SECONDS)
OFF DELAY SELECTOR
BLOWER HEAT
FUSE
3A
24VAC
RESET
AUXILIARY
LIMITS
M1
GAS
VALVE
C2
YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BU BLUE
GY GRAY
RD RED
COLOR CODES:
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
22314801 REV.01
OR (MED LOW)
BU (MED)
RD (LOW)
GAS VALVE
C2
M1
C
G
R
W
INTERNAL TO
INTEGRATED CONTROL
JUNCTION
EQUIPMENT GND
FIELD GND
DIAGNOSTIC
LED
2 CIRCUIT
CONNECTOR
HOT
SURFACE
IGNITER
OVERCURRENT
PROT. DEVICE
IGNITER
TH (3)
INTEGRATED
CONTROL MODULE
JUNCTION BOX
LINE-H
LINE-N
XFMR-H
IN
T
E
G
R
A
T
E
D
CO
NT
RO
L
M
O
DUL
E
IN
T
E
G
R
A
T
E
D
CO
NT
RO
L
M
O
D
U
L
E
GND
DISCONNECT
L
N
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
OVERCURRENT PROTECTION DEVICE
BR
GY
RD
BU
BK
4. IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER
BEFORE CONNECTING BLOWER LEADS. UNUSED BLOWER LEADS MUST BE PLACED ON
"PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
TERMINAL
SWITCH (PRESS.)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
PK PINK
115 VAC HOT AND PARK TERMIN ALS
LINE-H
FLAME SENSOR
FRONT COVER
PRESSURE SWITCH
( SINGLE CONTROL ON 45K BTU )
NO
C
GY
BK
PLUG CONNECTION
FIELD SPLICE
SWITCH (TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
BU
GN
GND
115 VAC
24 VAC
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
DOOR
SWITCH
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
BK
GND
DISCONNECT
L
N
PO
W
ER
S
UP
PLY
W
IT
H
OV
ER
CU
RR
EN
T P
RO
TE
CT
IO
N
DE
VIC
E
WH
JUNCTION
BOX
1
TO
115
V
AC
/ 1
0/6
0H
Z
OR
ID BLOWER
PRESSURE
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER COMPARTMENT
BLOWER COMPARTMENT
NOTE 4
SEE
N O
COOL-H
BK (HI)
BR
BR
CAPACITOR
YL
WH
YL
CONTROL
PRIMARY LIMIT
AUTO RESET
BU
VT
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
RD
OR
PK
BK
WH
WH
BLOWER
INDUCED DRAFT
MANUAL RESET
AUXILIARY LIMITS
(1) IN UPFLOW
BLOWER DECK
(2) IN C'FLOW
BLOWER HOUSING
C
CIRCULATOR
BLOWER
FP (2)
LIMIT CONTROLS
MANUAL RESET AUXILIARY
HE
AT
CO
OL
HUM-N
IGNITER
HOT SURFACE
XFMR-N
IND
HUM-H
IGN
COOL-H
CIR-N
HEAT-H
EAC-N
EAC-H
AIR CLEANER
ELECTRONIC
BLWR
CIRCULATOR
BLWR
ID
HUMIDIFIER
FLAME SENSOR
115 VAC
TRANSFORMER
40 VA
24 VAC
GND
CONTROL
LIMIT
PRIMARY
AUTO RESET
(SINGLE CONTROL ON 45K BTU)
LIMIT CONTROL(S)
MANUAL RESET ROLLOUT
RO1 (5)
RO2 (11)
HLO (1)
HLI (7)
MVC (9)
GND (8)
TR (6)
OR
WH
WH
BU
YL
OR
RD
GN
BR
VT
PK
PK
GY
WH
CO
NN
E
C
T
O
R
9
CI
RCUI
T
1
15 V
A
C
NE
UT
RA
L
VT
BK
BK
BK
GY
2
4
V
T
H
E
R
M
O
S
T
A
T
C
O
NNE
CT
IO
NS
MICRO
TO
C
G
Y
W
R
TRANSFORMER
40 VA
2
WH
OR
BU
YL
OR
OR
GY
PK
RD
OR
GY
WH
LINE-N
XFM R-N
XF
M
R
-H
TE
R
M
IN
A
L
S
CIRC-N
BU
GY
GN
BR
1
2
3
12
11
10
9
8
7
6
5
4
WARNING:
RATING OF AT LEAST 105
°C. USE COPPER CONDUCTORS ONLY.
24 VAC
HUMIDIFIER
24 VAC
HUMIDIFIER
HUMIDIFIER
PSO (4)
MV (12)
PS (10)
C
NO
C
NO
FRONT COVER
PRESSURE SWITCH
ID BLOWER
PRESSURE
SWITCH
0
C
7
6
5
4
3
2
1
OFF = CONTROL FAILURE
STEADY ON = NORMAL OPERATION
1 FLASH =
2 FLASHES = PRESSURE SWITCH STUCK CLOSED
3 FLASHES = PRESSURE SWITCH STUCK OPEN
4 FLASHES = OPEN HIGH LIMIT
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE
OPEN ROLLOUT
7 FLASHES = LOW FLAME SIGNAL
6 FLASHES =
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)
CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
180
BLOWER HEAT
DIP SWITCHES
*
150
90
OFF DELAY SELECTOR
*
120
AS SHIPPED
FROM FACTORY
ON
CONTROL
(SECONDS)
MODULE
OFF
ON
ON
OFF
OFF
OFF
ON
INTEGRATED
FUSE
R
COOL-H
Y TWIN
Summary of Contents for GMS95
Page 34: ...34...