Expanded Cooling Data — GSZ140481K* + ARUF61D14** + TXV (cont.)
Outdoor Ambient T
emp
er
ature
65ºF
75ºF
85ºF
95ºF
105ºF
115ºF
Entering Indoor W
et Bulb T
emper
ature
IDB
Airfl
ow
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
80
1400
MBh
46.1
46.8
48.2
50.2
45.7
46.4
47.8
49.8
44.5
45.2
46.6
48.6
42.5
43.1
44.5
46.6
40.0
40.6
42.0
44.1
37.7
38.3
39.7
41.8
S/T
1.00
0.82
0.68
0.54
1.00
0.83
0.69
0.54
1.00
0.86
0.72
0.57
1.00
0.88
0.74
0.59
1.00
1.00
0.76
0.61
1.00
1.00
0.81
0.66
Delt
a T
27
25
22
18
27
25
22
18
27
25
22
18
27
25
22
18
26
25
21
18
27
26
22
19
KW
2.79
2.78
2.78
2.80
3.11
3.10
3.10
3.12
3.46
3.46
3.46
3.48
3.85
3.85
3.84
3.87
4.28
4.28
4.28
4.30
4.79
4.79
4.78
4.81
AMPS
10.2
10.2
10.2
10.3
11.7
11.7
11.6
11.7
13.3
13.3
13.3
13.4
15.1
15.1
15.0
15.1
17.1
17.0
17.0
17.1
19.4
19.4
19.3
19.4
HI PR
256
258
259
264
297
298
300
304
339
340
342
346
384
386
387
392
433
435
436
441
486
487
489
493
LO PR
123
124
128
133
130
132
135
140
137
138
142
147
142
144
147
152
148
149
152
158
155
156
159
164
1560
MBh
46.6
47.3
48.7
50.8
46.2
46.9
48.3
50.3
45.0
45.7
47.1
49.1
43.0
43.6
45.0
47.1
40.5
41.1
42.5
44.6
38.2
38.8
40.2
42.3
S/T
1.00
0.87
0.73
0.59
1.00
0.88
0.74
0.59
1.00
0.91
0.77
0.62
1.00
1.00
0.79
0.64
1.00
1.00
0.81
0.66
1.00
1.00
0.86
0.71
Delt
a T
26
24
21
17
26
24
21
17
26
24
21
18
26
24
21
17
26
24
20
17
27
25
22
18
KW
2.80
2.80
2.79
2.82
3.12
3.12
3.11
3.14
3.48
3.48
3.47
3.49
3.86
3.86
3.86
3.88
4.30
4.29
4.29
4.31
4.80
4.80
4.80
4.82
AMPS
10.3
10.2
10.2
10.3
11.7
11.7
11.7
11.8
13.4
13.4
13.3
13.4
15.1
15.1
15.1
15.2
17.1
17.1
17.1
17.2
19.4
19.4
19.4
19.5
HI PR
258
259
261
266
299
300
301
306
341
342
344
348
386
387
389
394
435
436
438
443
488
489
490
495
LO PR
124
126
129
134
132
133
136
142
138
140
143
148
144
145
149
154
149
151
154
159
156
158
161
166
1800
MBh
47.6
48.2
49.6
51.7
47.1
47.8
49.2
51.2
46.0
46.6
48.0
50.1
43.9
44.5
45.9
48.0
41.4
42.0
43.4
45.5
39.1
39.7
41.1
43.2
S/T
1.00
0.91
0.77
0.62
1.00
0.92
0.78
0.63
1.00
0.95
0.80
0.66
1.00
1.00
0.82
0.68
1.00
1.00
0.85
0.70
1.00
1.00
0.90
0.75
Delt
a T
25
23
20
16
25
23
20
16
25
23
20
16
25
23
20
16
24
23
19
16
26
24
20
17
KW
2.82
2.81
2.81
2.83
3.14
3.13
3.13
3.15
3.49
3.49
3.49
3.51
3.88
3.88
3.87
3.90
4.31
4.31
4.31
4.33
4.82
4.82
4.81
4.84
AMPS
10.3
10.3
10.3
10.4
11.8
11.8
11.8
11.9
13.4
13.4
13.4
13.5
15.2
15.2
15.2
15.3
17.2
17.2
17.2
17.3
19.5
19.5
19.5
19.6
HI PR
261
262
264
268
301
302
304
308
343
344
346
351
389
390
392
396
438
439
441
445
490
491
493
498
LO PR
127
128
132
137
134
136
139
144
141
142
145
151
146
148
151
156
152
153
156
162
159
160
163
168
85
1400
MBh
46.9
47.6
48.9
51.0
46.5
47.2
48.5
50.6
45.3
46.0
47.3
49.4
43.3
43.9
45.3
47.4
40.7
41.4
42.8
44.8
38.4
39.1
40.5
42.6
S/T
1.00
0.93
0.79
0.64
1.00
0.94
0.80
0.65
1.00
1.00
0.82
0.67
1.00
1.00
0.84
0.69
1.00
1.00
0.86
0.72
1.00
1.00
1.00
0.77
Delt
a T
30
28
25
22
30
28
25
22
30
29
25
22
30
28
25
22
30
28
25
21
31
29
26
22
KW
2.79
2.79
2.78
2.81
3.11
3.11
3.11
3.13
3.47
3.47
3.46
3.49
3.86
3.86
3.85
3.87
4.29
4.29
4.28
4.31
4.80
4.79
4.79
4.81
AMPS
10.2
10.2
10.2
10.3
11.7
11.7
11.7
11.8
13.3
13.3
13.3
13.4
15.1
15.1
15.1
15.2
17.1
17.1
17.0
17.2
19.4
19.4
19.4
19.5
HI PR
258
259
261
265
298
299
301
305
340
341
343
348
386
387
389
393
435
436
438
442
487
488
490
494
LO PR
125
126
129
135
132
134
137
142
139
140
143
149
144
146
149
154
150
151
154
159
156
158
161
166
1560
MBh
47.4
48.1
49.4
51.5
47.0
47.7
49.0
51.1
45.8
46.5
47.8
49.9
43.8
44.4
45.8
47.9
41.2
41.9
43.3
45.3
38.9
39.6
41.0
43.1
S/T
1.00
0.98
0.84
0.69
1.00
0.98
0.84
0.70
1.00
1.00
0.87
0.72
1.00
1.00
0.89
0.74
1.00
1.00
0.91
0.77
1.00
1.00
1.00
0.82
Delt
a T
29
28
24
21
29
27
24
21
30
28
24
21
29
27
24
21
29
27
24
21
30
28
25
22
KW
2.81
2.80
2.80
2.82
3.13
3.12
3.12
3.14
3.48
3.48
3.48
3.50
3.87
3.87
3.86
3.89
4.30
4.30
4.30
4.32
4.81
4.81
4.80
4.83
AMPS
10.3
10.3
10.3
10.4
11.8
11.7
11.7
11.8
13.4
13.4
13.4
13.5
15.2
15.2
15.1
15.2
17.1
17.1
17.1
17.2
19.5
19.5
19.4
19.5
HI PR
259
261
262
267
300
301
303
307
342
343
345
349
387
389
390
395
436
438
439
444
489
490
492
496
LO PR
126
128
131
136
134
135
138
144
140
142
145
150
146
147
150
156
151
153
156
161
158
159
162
168
1800
MBh
48.3
49.0
50.3
52.4
47.9
48.6
49.9
52.0
46.7
47.4
48.7
50.8
44.7
45.3
46.7
48.8
42.2
42.8
44.2
46.3
39.9
40.5
41.9
44.0
S/T
1.00
1.00
0.88
0.73
1.00
1.00
0.88
0.74
1.00
1.00
0.91
0.76
1.00
1.00
0.93
0.78
1.00
1.00
0.95
0.80
1.00
1.00
1.00
0.86
Delt
a T
28
26
23
20
28
26
23
20
28
27
23
20
28
26
23
20
28
26
23
19
29
27
24
21
KW
2.82
2.82
2.82
2.84
3.14
3.14
3.14
3.16
3.50
3.50
3.49
3.52
3.89
3.89
3.88
3.90
4.32
4.32
4.31
4.34
4.83
4.82
4.82
4.84
AMPS
10.4
10.4
10.3
10.4
11.8
11.8
11.8
11.9
13.5
13.5
13.4
13.5
15.2
15.2
15.2
15.3
17.2
17.2
17.2
17.3
19.5
19.5
19.5
19.6
HI PR
262
263
265
269
302
303
305
310
345
346
347
352
390
391
393
397
439
440
442
446
491
492
494
499
LO PR
129
130
133
139
136
138
141
146
143
144
147
153
148
150
153
158
154
155
158
163
160
162
165
170
IDB: En
tering Indoor Dr
y Bulb T
emper
atur
e
Shaded ar
ea r
eflects AHRI Ra
ting Conditions.
kW = T
ot
al s
ys
tem po
w
er
High and lo
w pr
essur
es ar
e measur
ed a
t the liquid and suction ser
vice v
alv
es.
Amp
s = Out
door unit amp
s (c
ompr
essor + f
an)