background image

4

Quick Installation Guide V1.0-2022-03-20

No.

Name

Description

1

DHCP

•  Enable DHCP when the router is in dynamic IP mode.

•  Disable DHCP when a switch is used or when the router 

is in static IP mode.

2

IP Address

• 

Do not configure the parameters when DHCP is enabled.

• 

Configure the parameters according to the router or 

switch information when DHCP is disabled.

3

Subnet Mask

4

Gateway Address

5

DNS Server

Troubleshooting

04

No.

Problem

Solutions

1

Cannot find CCM-

BLE**

1.  Make sure that the inverter is powered on and the Ezlink 

device is connected properly.

2.  Make sure that the smart device is within the 

communication range of the Ezlink device.

3.  Restart the inverter or short press to restart the Ezlink.

2

Unable to connect to 

CCM-BLE**

1.  Make sure that no other smart device is connected to 

Solar-WiFi**.

2.  Restart the inverter or short press to restart the Ezlink, 

then reconnect CCM-BLE**.

3

 Indicator double 

blink 

1.  Make sure that the router is powered on.

2.  Make sure that the the LAN cable is connected tightly.

4

 Indicator 

quadruple blink 

1.  Make sure that the cables are connected properly, and 

the router can access the internet.

2.  If the problem persists, contact the after sales service.

5

       Indicator off

•  Check whether the inverter is powered on.

Summary of Contents for Ezlink3000-US

Page 1: ...nd forward the data of the adapted inverter and transmit bidirectional encrypted data to the server through the protocol The board is connected to the inverter through the 5PIN interface to power itself and communicate with the inverter It supports Bluetooth protocol which allows device configuration information reading local diagnosis and other functions through Bluetooth communication The board ...

Page 2: ...aster App Step 2 Connect the app and the device Commissioning via PV Master App Step 3 Set communication settings of the device Commissioning 03 1 2 3 The interface may differ depending on the communication method Make sure that the WiFi RSSI value is higher than 60 50 or higher is recommended ...

Page 3: ...3 Quick Installation Guide V1 0 2022 03 20 5 4 When the RSSI value is less than 60 you should move the router closer to the device remove the obstacle or add a repeater to improve the signal strength ...

Page 4: ...ink device is connected properly 2 Make sure that the smart device is within the communication range of the Ezlink device 3 Restart the inverter or short press to restart the Ezlink 2 Unable to connect to CCM BLE 1 Make sure that no other smart device is connected to Solar WiFi 2 Restart the inverter or short press to restart the Ezlink then reconnect CCM BLE 3 Indicator double blink 1 Make sure t...

Page 5: ...Parameters 4G 3G Communication optional LTE FDD B2 B4 B5 B12 B13 B14 B66 B71 WCDMA B2 B4 B5 WiFi Communication 802 11 b g n 2412MHz 2462MHz Environment Parameters Operating temperature range 30 60 C Storage temperature range 30 70 C Relative humidity range 0 100 No consideration Max operating altitude 4000m Technical Data 05 Website GoodWe Technologies Co Ltd No 90 Zijin Road suzhou Jiangsu China ...

Page 6: ...erated with minimum distance 20cm between the radiator your body FCC Label Instructions If using a permanently affixed label the modular transmitter must be labeled with its own FCC identification number and if the FCC identification number is not visible when the module is installed inside another device then the outside of the device into which the module is installed must also display a label r...

Page 7: ...luation may be required as specified by 2 1093 6 Antenna Antenna type monopole antenna Peak antenna gain 2 5 dBi 7 Label and compliance information An exterior label on OEM s end product can use wording such as the following Contains Transmitter Module FCC ID 2AU7JEZLINK3000 US or Contains FCC ID 2AU7JEZLINK3000 US 8 Information on test modes and additional testing requirements 9 The modular trans...

Page 8: ...itional testing Part 15 Sub part B disclaimer The final host module combination need to be evaluated against the FCC Part 15B criteria for unintentional radiators in order to be properly authorized for operation as a Part 15 digital device The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical ass...

Page 9: ...abled Testing laboratories may need to add attenuation or filters depending on the signal strength of any active beacons if applicable from the enabled radio s See ANSI C63 4 ANSI C63 10 and ANSI C63 26 for further general testing details The product under test is set into a link association with a partnering device as per the normal intended use of the product To ease testing the product under te...

Reviews: