17
05 Installation
User Manual V1.0-2022-08-20
5.2 Inverter Installation
5.2.1 Moving the Inverter
CAUTION
• Operations such as transportation, turnover, installation and so on must meet the
requirements of the laws and regulations of the country or region where it is located.
• Move the inverter to the site before installation. Follow the instructions below to avoid
personal injury or equipment damage.
1.
Consider the weight of the equipment before moving it. Assign enough personnel to
move the equipment to avoid personal injury.
2. Wear safety gloves to avoid personal injury.
3. Keep balance to avoid falling down when moving the equipment.
NOTICE
•
Avoid the water pipes and cables buried in the wall when drilling holes.
• Wear goggles and a dust mask to prevent the dust from being inhaled or contacting eyes
when drilling holes.
•
The DC switch lock shall be prepared by customers with hole diameter: φ8mm (0.31in).
Select appropriate size. Otherwise it is unable to finish the installation.
•
The DC switch lock shall be prepared by customers with hole diameter: φ10mm (0.39in).
Select appropriate size. Otherwise it is unable to finish the installation.
•
Make sure the inverter is firmly installed in case of falling down.
Step 1
Put the mounting plate on the wall or the support horizontally and mark positions for
drilling holes.
Step 2
Drill holes to a depth of 80mm (3.15in) using the hammer drill. The diameter of the drill
bit should be 10mm (0.39in).
Step 3
Secure the mounting plate using the expansion bolts.
Step 4
Secure the DC switch with the DC switch lock, ensuring that the DC switch is "OFF" during
installation.
Step 5
Install the inverter on the mounting plate.
Step 6
Tighten the nuts to secure the mounting plate and the inverter.
Step 7
Install the anti-theft lock.