42
User Manual V1.0-2022-08-20
10 Technical Parameters
Output Voltage Range (V)(at 208V)
(according to local standard)
183~229
183~229
183~229
Nominal AC Grid Frequency (Hz)
60
60
60
AC Grid Frequency Range (Hz)
58~62
58~62
58~62
Max. Output Current (A)
20.8
25.0
31.7
Max. Output Fault Current (Peak
and Duration) (A/ms)(at 20us)
68
68
68
Inrush Current (Peak and Duration)
(A/us)(at 20us)
58
58
58
Nominal Output Current (A)
20.8
25.0
31.7
Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion
<3%
Maximum Output Overcurrent
Protection (A)
68
68
68
Efficiency
Max. Efficiency
97.5%
97.5%
97.5%
CEC Efficiency(at 240V)
96.5%
96.5%
96.5%
CEC Efficiency(at 208V)
96.0%
96.0%
96.5%
Protection
PV String Current Monitoring
Integrated
PV Insulation Resistance Detection
Integrated
Residual Current Monitoring
Integrated
PV Reverse Polarity Protection
Integrated
Anti-islanding Protection
Integrated
AC Overcurrent Protection
Integrated
AC Short Circuit Protection
Integrated
AC Overvoltage Protection
Integrated
DC Switch
Integrated
DC Surge Protection
Type III (Type II Optional)
AC Surge Protection
Type III (Type II Optional)
AFCI
Integrated
Rapid Shutdown
Integrated
Power Supply at Night
Integrated
General Data
Operating Temperature Range (°F)
-13~+140(-25℃~60℃)
Relative Humidity
0~95%
Max. Operating Altitude (ft)
9842 (3000m)