background image

TAIYO ELECTRIC IND. CO., LTD. 

NC-100R

N

2

 STATION

Thank you for buying the 

 NC-100R

 N

2

 Station. 

This product has been engineered and manufactured to goot high standards for dependability, 
ease of operation, and operator safety. If you follow the instructions and safety precautions in 
this manual and on the product, and use the N

2

 Station properly and only for what it is intended, 

you will enjoy years of safe, reliable service.  

Operation 

Manual

WARNING 

Before using the NC-100R, please read the Operation Manual. 
Failure to follow the safety precautions and instructions in this 
manual could result in serious injury and property damage.

KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE 

Summary of Contents for NC-100R

Page 1: ...N2 N2 Station NC 100R NC 100R See English version from P 9...

Page 2: ...L min 0 5 4 0 L min 60 185 L 118 W 112 H 2Kg N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATION NC 100R ON OFF 1 5 2 5 2 0 1 0 0 5 3 0 3 5 4 0 L min 0 N2 OUT N2 STATIO...

Page 3: ...3 4 4 1 N2 1 10 N2 4 2 OFF 2 80 0 01mg m3 0 01 m RX 802ASPH 0 5 1 5 L min 0 7MPa N2 99 9 99 7 99 2 98 3 N2 L min 0 5 1 0 1 5 2 0 N2 RX 802ASPH 3 N2 4 N2...

Page 4: ...4 4 2 NC 1 00R SER NO AIR IN MAX 0 7MPA N2 4mm N2 0 5 4 0 L min N2 N2 ON OFF 0 7MPa 6mm...

Page 5: ...5 N2 0 7MPa 7kgf c 0 7MPa N2 NC 100R 5...

Page 6: ...6 5 1 NC 100R RX 802ASPH 1MPa 0 3 0 7MPa NC 100R N2 NC 100R 6mm RX 802ASPH 2...

Page 7: ...7 5 2 N2 N2 3 SMC AF20 01 AFM20 01 N2 N2 N2 0 7MPa N2 0 7MPa 0 7MPa SMC AWD20 01E 1 1 8...

Page 8: ...8 6 7 N2 1 1 1 1 No NC 6 2m B1072YG00 N2 N2 5 1 NC 100R 1 0L min 1 8 2...

Page 9: ...structions and safety precautions in this manual and on the product and use the N2 Station properly and only for what it is intended you will enjoy years of safe reliable service Operation Manual WARN...

Page 10: ...Input Air Temperature 5 C 50 C Nitrogen Generation Density More than 99 5 0 7MPa 0 5L min Recommended Nitrogen Generation Flow Rate 1 0L min Flow Meter 0 5 4 0 L min Max Environmental Temp 60 C Dimens...

Page 11: ...than 0 01mg m3 Particles Less than 0 01 m RX 802ASPH 0 5 1 5 L min When the air pressure supplied is 0 7MPa Nitrogen Density 99 9 99 7 99 2 98 3 Nitrogen Flow rate L min 0 5 1 0 1 5 2 0 Requirements f...

Page 12: ...4mm Nitrogen Flow Meter Measurement Range 0 5 4 0 L min Nitrogen Flow Regulation Turn to left Increase flow Turn to right Decrease flow Nitrogen Output Valve Turn to left ON Turn to right OFF Please...

Page 13: ...disconnect or even explode Compressed air supplied by the compressor can contain water oil or dust Make sure these elements do not enter the unit by using appropriate filters Please note that Nitrogen...

Page 14: ...mm diameter tube included with the station It can be attached Connect to Compressed Air Input on the back of the unit Temperature Controlled Lead free applicable Soldering Station The tube from the ha...

Page 15: ...to protect the Micro Mist Separator Micro Mist Separator Recommended see below The Micro Mist Separator removes the tiny particles and oil droplets in the air that could not be removed by the Air Filt...

Page 16: ...r nearest distributor NOTE The Nitrogen Gas Separation Membrane inside this device is not available as a replacement part Please return the unit to your distributor to have this repaired At the follow...

Reviews: