1
6. Troubleshooting
Trouble: The solder does not melt.
a) The temperature setting display does not flash
Cause
Countermeasure
The Power Cord is unplugged at either end.
Plug it in.
The Power Switch is in the OFF position.
Set the power switch to the ON position
The Power Cord is damaged.
Replace the power cord.
The Fuse is blown.
Replace the fuse.
b) The temperature setting display flashes
Cause
Countermeasure
The set temperature is lower than the
temperature at which the solder melts.
Set the temperature to higher than that the solder
melting temperature.
The heater is damaged.
Replace the heater.
The alarm code display is shown.
Check the alarm code table in the SDC15
operation manual.
Return your
goot
distributor for service if you cannot solve the trouble above.
7. Replacement Parts
7.1 Replacement Parts
No. Item
No. Item
1
Heater (110 - 130V)
Heater (220 - 240V)
5
Heat Resistant Board Set B-50 for
POT-50C
2
Heater Block *Not required for POT-50C
3
Cast Iron Bath for POT-50C *Built-in heater
block
6
Dross Tray
7
Spatula
4
Fuse 15A 250V for 110-130V model
Fuse 10A 250V for 220-240V model
8
Power Cord
7.2 Replacement Procedures
POT-50C
Top Plate A
Top Plate B
⑧
①
④
⑤
⑥
⑦
③
WARNING
Turn the unit OFF and unplug the power outlet before changing the solder bath, heater or heat
resistant board. Do not start removing the solder bath or the parts before the unit has completely
cooled down.