background image

 

6. Troubleshooting 

 
Trouble: The solder does not melt. 
 
a)  The temperature setting display does not flash 

 

Cause 

Countermeasure 

The Power Cord is unplugged at either end. 

Plug it in. 

The Power Switch is in the OFF position. 

Set the power switch to the ON position 

The Power Cord is damaged. 

Replace the power cord. 

The Fuse is blown. 

Replace the fuse. 

 
b)  The temperature setting display flashes 
 

Cause 

Countermeasure 

The  set  temperature  is  lower  than  the 
temperature at which the solder melts. 

Set  the  temperature to  higher than  that  the  solder 
melting temperature. 

The heater is damaged. 

Replace the heater. 

The alarm code display is shown. 

Check  the  alarm  code  table  in  the  SDC15 
operation manual.   

 
Return your 

goot

 distributor for service if you cannot solve the trouble above.

 

 
 
 

7. Replacement Parts 

 

7.1 Replacement Parts 

 

No.  Item 

No.  Item 

Heater (110 - 130V) 
Heater (220 - 240V) 

Heat Resistant Board Set B-50 for 
POT-50C 

Heater Block    *Not required for POT-50C 

Cast  Iron  Bath  for  POT-50C  *Built-in  heater 
block 

Dross Tray 

Spatula 

Fuse 15A 250V for 110-130V model 
Fuse 10A 250V for 220-240V model 

Power Cord 

 
 

7.2 Replacement Procedures 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

POT-50C 

Top Plate A 

Top Plate B 

 

 

 

 

 

 

 

WARNING 

Turn the unit OFF and unplug the power outlet before changing the solder bath, heater or heat 
resistant board. Do not start removing the solder bath or the parts before the unit has completely 
cooled down. 

 

Summary of Contents for POT-50C

Page 1: ...F Solder Bath Temperature Room temp 500o C 932o F Unit Dimensions 174 W x 285 D x 142 H 6 9 X 11 2 x 5 6 inch Solder Bath Dimensions 50 W x 50 D x 50 H 2 x 2 x 2 inch Weight Approx 4Kg 75 lb Max Solde...

Page 2: ...heat from the heater can ignite fumes Be sure that the work area is well ventilated 2 KEEP CHILDREN AND BYSTANDERS AWAY FROM THE SOLDER POT Do not let bystanders touch the solder pot All bystanders s...

Page 3: ...is heavy when filled with solder and the solder bath and surrounding area becomes very hot Unplug the solder pot power cord immediately if there is burnt smell or unusual heating occurs Do not use th...

Page 4: ...parameter settings please refer the SDC15 operation manual included with this solder pot You can change the temperature display from Celsius to Fahrenheit Para key No need to use Changes the displayed...

Page 5: ...put for over 2 seconds during the setting the flashing value will be confirmed automatically and operation display will be shown Note 2 It is not possible to set the values to more than the maximum te...

Page 6: ...the heater The alarm code display is shown Check the alarm code table in the SDC15 operation manual Return your goot distributor for service if you cannot solve the trouble above 7 Replacement Parts 7...

Page 7: ...out with the heater when removing Reinsert the sleeve in heater opening 5 Remove the M4 screw of the terminal block and remove the ground terminal for the solder pot 6 Loosen the Bath Fixing Screw on...

Page 8: ...rvice accessories and etc Contact your nearest distributor or following SOLDERING IRONS EQUIPMENT ACCESSORIES TAIYO ELECTRIC IND CO LTD www goot co jp TEL 81 84 951 1512 FAX 81 84 951 9531 A4190HL00 2...

Reviews: