Unload Stop
Optional feature utilizing Anti-Recoil detection. When user sets a weight onto a surface in
Float Mode, it is terminated if Anti-Recoil detects an unloading. This can be useful for
applications needing a quick Float Mode exit to an idle state to allow user to work on the part.
Note
: As a result of the extra detection, Float Mode is likely to terminate when the upper limit
switch is hit while unit is running at a fast speed. This false detection can be avoided or
reduced by running the unit at a low speed or maintaining a distance from the upper limit.
Anti-Recoil
Force On/Off
Over-Force Detection: Unit terminates Float
Mode if user’s operating force exceeds the
maximum force limit or a dropped weight is
detected by evaluating the force
profile.
Select
This is to choose Force ON detection force.
(15 to 45 lbs. in increments of 5 lbs.)
Overload
Tare
Set the overload limit to the current load
weight.
Overload Limit
Program an overload limit.
Operator force
Configure operating force limit for moving a
load in air. Refer to I&O Manual for details.
Sensitivity
Configure overload detection sensitivity.
Set
When you make changes to either overload
limit, operator force, or sensitivity, the set
button must be pressed.
Default
Sets overload settings to default
76