STEP 5A - IN-LINE SLIDE & IN-LINE FORCE SENSING HANDLE INSTALLATION
5A.1
Ensure the wire rope is still fed through the center
of the coil cord. Hold the slide handle just below
the coil cord.
5A.2
Center the coil cord footer between the ears of
the slide handle swivel.
Note:
Make sure the fin
of the coil cord footer is on the opposite side of
the slide handle connector.
5A.3
Remove the 16mm shoulder bolt from the coil
cord footer and wire rope and allow the coil cord
footer and wire rope to slide down into the slide
handle swivel.
16 mm Shoulder Bolt
Slide Handle Connector
Wire Rope
Coil Cord Footer
M12 Jam Nut
**COIL CORD
HAS BEEN
REMOVED FOR
CLARITY
5A.4
Once the wire rope, coil cord footer and slide handle
swivel are aligned, replace the 16mm shoulder bolt, thereby capturing
the wire rope, coil cord footer and slide handle (
diagram 5A1
).
5A.5
Thread the coil cord connector into the slide handle connector (
diagram
5A1
).
5A.6
Thread the M12 jam nut onto the 16mm shoulder bolt.
5A.7
Check that the coils of the coil cord are centered around the wire rope
when properly installed.
5A.8
Optional:
Install the hook or tooling using the retaining nut and lock
washer. The included flat washer is unnecessary in this application. Use
the open pilot hole on the Slide Handle Retaining Nut and a #21 drill bit
Diagram 5A2.
Slide
Handle with Optional Pin.
to drill a hole completely through the threads of the hook and the opposite side of the nut. Hammer
the included M4x36mm spring into the hole until it is flush with the surface of the nut (
diagram 5A2
).
5A.9
Continue to Step 6 on page 21.
STEP 5B - REMOTE MOUNTED SLIDE HANDLE INSTALLATION
5B.1
Ensure the wire rope is still fed through
the center of the coil cord. Hold the
G360™ swivel just below the coil cord
assembly.
5B.2
Center the coil cord footer between the
ears of the G360™ swivel.
Note:
Make
sure the fin of the coil cord footer is on the
opposite side of the G360 connector.
5B.3
Remove the 16mm shoulder bolt from the
coil cord footer and wire rope and allow
the coil cord footer and wire rope to slide
down into the G360 swivel.
**COIL CORD HAS BEEN
REMOVED FOR CLARITY
G360 Swivel
STRAIN-RELIEF CLAMP - MUST BE USED
TO PREVENT DAMAGE TO G360.
Diagram 5A1.
Slide Handle,
Shoulder Bolt and Coil Cord
Diagram 5B1.
G360, Shoulder
Bolt, and Coil
Cord
11