LED Chart:
The chart below shows the status of LED lights in di
ff
erent states.
Machine State
Sub-State (if applicable)
Color
LED TEXT
E-Stop Engaged
- -
No Light
E-STOP ENGAGED
Programming Mode
Amber
PROGRAMMING MODE
PLC (Command) Fault
Flashing Red
COMMAND FAULT
ERROR NUMBER:
####
Drive Fault
Flashing Red
DRIVE FAULT
ERROR NUMBER:
#####
Warning
Amber
WARNING ####
Service Warning
Amber
SRV WARN <###> HRS
Service Mode
Amber
SERVICE MODE
Run Mode
Overload
Red
WARNING LIFT OVERLOAD
Overspeed
No Light
FLOAT MODE
OVERSPEED
Handle Idle Timeout
Amber
IDLE TIME EXCEEDED
Handle Mode
Green
RUN MODE HANDLE
Float Mode
Blue
RUN MODE FLOAT
Ready Mode
- -
No Light
G-FORCE READY TO LIFT
Startup Sequence
Before Ready Mode
No Light
SYSTEM BOOTING
COMMUNICATION INITIALIZ-
ING
POWERED ON
G-Force Ini
Ɵ
alizing
- -
No Light
G-FORCE INITIALIZING
User is connected to the
unit with user interface*
Flashing Amber
HMI USER INTERFACE
IS ACTIVE
*
Service level 2 or OEM level 3 user is logged in.
G-Force® & Easy Arm Q2 - iQ2 Service Manual
Gorbel Inc.
Revised 5/21
6 - 2