Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Re-
fer to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O
page of the visualization to correct the invalid setting.
(a) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262 for further instruction
.
Error #322 - ERROR_INPUT_CONFIGURATION_OUT_OF_BOUND
Description:
At startup, found a Q2/iQ2 feature input channel con
fi
guration setting is outside the allowable
range.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Re-
fer to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O
page of the visualization to correct the invalid setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262 for further instruction
.
Error #323 - ERROR_OUTPUT_CONFIGURATION_OUT_OF_BOUND
Description:
At startup, found a Q2/iQ2 feature input channel con
fi
guration setting is outside the allowable
range.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Re-
fer to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O
page of the visualization to correct the invalid setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262 for further instruction
.
Error #324 - ERROR_FALSE_SETTING_CUS_MULTIPLE_VL_SETS
Description:
At startup, found invalid con
fi
guration setting(s) for the multiple virtual limit (VL) sets standard Q2/
iQ2 feature.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
Cause / Remedy:
(a) Please review the con
fi
guration shown on the CONFIG I/O page of the visualization to correct the invalid
setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262.
Error #326 - ERROR_MISSING_INPUT_CHANNEL
Description:
At startup, found an Q2/iQ2 feature is miscon
fi
gured, speci
fi
cally a required digital input channel
location is missing.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup. Handle
displays this command fault followed by an extended error index number (S#) referencing the Q2/iQ2 feature
with the invalid setting.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Re-
fer to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O
page of the visualization to correct the invalid setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262.
Error #327 - ERROR_MISSING_OUTPUT_CHANNEL
Description:
At startup, found an iQ2 feature is miscon
fi
gured, speci
fi
cally a required digital output channel
location is missing.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup. Handle
dis- plays this command fault followed by an extended error index number (S#) referencing the iQ2 feature with
the invalid setting.
Cause / Remedy:
(a) Use the extended error index number (S#) to identify which Q2/iQ2 feature contains the invalid setting (Re-
fer to table at end of Command Fault Error list). Please review the con
fi
guration shown on the CONFIG I/O
page of the visualization to correct the invalid setting.
(b) Please contact Gorbel® After the Sales Service at 800-821-0086 or 585-924-6262.
Error #331 - ERROR_X67_1_IO_MASK_SETUP
Description:
At startup, unit detects an error while con
fi
guring the
fi
rst X67 spare IO module based on the con-
fi
guration setting.
Reaction:
Lift program terminates processing to prevent running with an incorrect con
fi
guration setup.
G-Force® & Easy Arm Q2 - iQ2 Service Manual
Gorbel Inc.
Revised 5/21
6 - 11