STEP 12 - RUNWAY CONDUCTOR BAR INSTALLATION (SAFE-LEC) (CONT.)
(for Safpowrbar® Runway Conductor Bar Installation, proceed to Step 13, page 20)
12.4
Attach collector bracket to side of endtruck
according to
Diagram 12E
. Bracket may be
tack welded or bolted into place. If bolting,
locate the bracket as shown, mark the hole
locations, and drill three Ø3/8” holes.
12.5
Slide the first collector onto the collector
bracket as shown in
Diagram 12F
.
12.6
Position collector so it lines up with the first conductor bar (
Diagram 12G
) and tighten
collector bolts to clamp it into place.
12.7
Run a minimum of 4COND 12AWG
SO(W) (recommended) cable from
collectors to electrical enclosure as
shown (
diagram 12H
).
12.8
Strip the end of the collector wire and
insert into the collector as shown in
Diagram 12J
.
12.9
Clamp the wire with the two screws. The
plastic screw should tighten down on the
wire’s insulation. When tightening the
clamping screw there will be some
resistance. Keep tightening until the wire
is clamped firmly in place.
12.10
Repeat steps 12.5 through 12.9 for the
remaining collectors.
Diagram 12E.
Diagram 12F.
Diagram 12G.
Diagram 12H.
Diagram 12J.
19
9/18 Rev. F