Eng. Edition 1.0 2004, Nov.
17
2.4 Settings
Control box functions
Function switch, level 0-9:
(dT, ”delta t”, is the temperature difference between start and stop of the burner.
Set switch-off temperature (boiler temp.) – dT = burner start temperature)
Level 0
Operation, dT 10
o
C.
Level 5
Boiler temperature setting
Level 1
Operation, dT 15
o
C.
Level 6
Low fan setting
Level 2
Operation, dT 20
o
C.
Level 7
High fan setting
Level 3
Operation, dT 25
o
C.
Level 8
Feed quantity, operation.
Level 4
Vacant
Level 9
Feed quantity, start.
Display with 10 lights in pile;
Standby/Start, Effect H(igh) and
Effect L(ow).
Indicator light;
Larm(
Alarm)/
Test,
red.
Indicator light;
On,
green.
Test
button.
Funkt
/Function witch 0-9
Pann Temp
/Boiler temp.
setting (switch off temp.)
Operating switch on/off.
Inställning
fläkt
i
l
ågeffektområdet.
Inställning
fläkt
i
h
ögeffektområdet.
Inställning pelletsmängd,
Startdos
.
Inställning pelletsmängd,
Driftdos
.
Display with 10 diodes;
Standby/Start, Effect H
(high)
and
Effect L
(low).
Indicator diode;
Larm
(
Alarm)/
Test,
red.
Indicator diode;
On,
green.
Test
button.
Funkt
/Function switch 0-9
Pann Temp
/Boiler temp.
setting (switch off temp.)
Operating switch on/off.
Settings:
Fläkt L
. Fan at low effect level
Fläkt H
. Fan at high effect level
Startdos
. Pellets feed quantity at start
Driftdos
. Pellets feed quantity during
operation