19
OPERATION
To select the functions of the hood, simply touch the controls.
T1. Standby mode
(the control panel off – all functions disabled) /
ON
(control panel switched on)
Note:
After about a minute of inactivity (suction and lights), the hood will automatically switch to standby.
T2. ON/OFF lights
- with the lights on, touch the LED strip
SL1
with the fingers towards right or left to increase or decrease the intensity of
the light.
Note:
the light turns on at the last set intensity before its switching off.
T3. ON/OFF
Automatic operation
The hood automatically sets the suction speed (power)
2
to increase if the environmental conditions detected by the
hood sensor require it.
If there are no variations in the environmental conditions, after 10 minutes (if the hood is already in suction speed
(power) 1), the hood turns off.
Note:
for a correct use of this function, first perform the "
Setting of the parameters for Automatic Operation
" (see
corresponding paragraph).
Note:
During automatic operation, if the user acts on the other functions that adjust the speed, auto ventilation function
is switched off.
T4. ON/OFF Motor
- with the motor running, touch the led strip
SL2
with your fingers towards right or left to increase or decrease the
suction speed (power).
Note
: the motor starts running at the last suction speed (power) set before switching off
.
T5. ON/OFF
Intensive suction
speed (power)
“POWER BOOST”
(timed)
Note:
After 5 minutes of operation the hood returns to its previous state.
T6. ON/OFF
intensive suction speed (power)
“POWER BOOST x 2”
(timed)
Note:
After
5 minutes of operation, the hood goes back to the previous status.
T7. ON/OFF
operation mode
"Air refresh
"
Every 50 minutes of inactivity, the suction speed (power
1
is turned on for 10 minutes.
T8. ON/OFF Delayed switch off
of the suction speed (power).
Note:
this function is available for the speeds that can be selected with button
T4
.
Press once or repeatedly to choose the delayed switch off time that you want to set (10-20-30 minutes)
T9. Indicator and reset filter saturation
The button lights on automatically with steady light when it is necessary to perform the grease filter maintenance.
The button lights on automatically with flashing light when it is necessary to perform the charcoal filter maintenance.
After performing the maintenance, with the hood off and the button active, press the button for more than 3 seconds to
perform the reset of the filter saturation indicator; repeat the operation if necessary (for ex., when both filters are
saturated).
Activation of the charcoal filter saturation indicator
The saturation indicator of the charcoal filter is normally disabled. To activate it, proceed in the following manner:
With the display on (ON) and the suction off (OFF), press simultaneously the buttons
T8
and
T9
for more than 3
seconds; the button
T9
lights on
with
steady light
for approx. 5 seconds, to indicate the activation.
To disable it, repeat the operation; the button
T9
will flash
for
approx. 5 seconds to indicate the disabling.
Setting of Automatic Operation parameters
For correct use of the automatic operation, perform "Hood Calibration" and "Selection of the hob".