• If a stationary appliance is not fitted with a supply cord and
a plug, or with other means for disconnection from the supply
mains having a contact separation in all poles that provide
full disconnection under overvoltage category III conditions,
the means for disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules. Using an
omnipolar switch with a contact separation of at least 3 mm
fitted in the supply cable will fulfil this requirement.
• The connection cable must hang freely and should not be
fed through a drawer.
• Gas connection 1/2” ISO 228 / ISO 7-1 / EN 10226-1
(1/2” ISO 228 / 1/2” ISO 228 FR only).
The gas connection must comply with national and local
regulations. See appliance label for technical gas data.
• This appliance is not connected to a combustion products
evacuation device. It shall be installed and connected in
accordance with current installation regulations. Particular
attention shall be given to the relevant requirements regarding
ventilation.
• We recommend that the gas hob be connected by means
of a fixed pipe. Connection using a specially designed safety
hose is also permitted.
• The pipe behind the oven must be made entirely out of metal.
• A safety hose may not be bent and must not come into
contact with moving parts of kitchen units.
17