8
until a regular minimum flame is obtained.
3. Re-assemble the knob and verify burner flame stability (when quickly rotating the
hand from maximum to minimum position the flame must not shut off).
4. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
Warning: these tasks may only be carried out by a qualified technician, authorized by the
gas distributing company or authorized service center!
TECHNICAL INFORMATION (TABLE 1)
GW65CLI --- GW65CLB
Appliance dimension (mm)
600
Operating voltage
220-240 V~, 50/60 Hz
Burner
A: Auxiliary burner (1,0kW)
SR: Semirapid burner (1,75kW)
R: Rapid burner (3,0kW)
TC: Bruciatore Tripla corona (3,8kW)
Front left
R
Rear left
-
Front central
SR
Rear central
A
Front right
TC
Rear right
-
Category Gas usage
G20/20mbar , G30/30mbar , G25/20mbar
Total Power (W)
9550
NOZZLE TABLE
Burner
A
SR
R
TC
Rated heat output (kW)
1.00
1.75
3.00
3.80
Ø INJECTOR (mm)
G30/G31 28..30/30-37mbar
0.50
0.65
0.85
0.98
G20
20mbar
0.72 - X
0.97 - Z
1.28 - H3
1.35 - K
G25
20mbar
0.77 - F1
1.00 - Y
1.26 - Y
1.52 - F3
Ø BY-PASS (mm)
G30/G31 28..30/30-37mbar
0.27
0.34
0.42
0.62
G20
20mbar
REG.
REG.
REG.
REG.
G25
20mbar
REG.
REG.
REG.
REG.