WARRANTY

The manufacturer guarantees correspondence of the alarm system to the Technical Requirements with the 

observance of operating conditions, installation, storage, transportation, stipulated in the given manual.

The item should pass the Quality Control department of the manufacturer. The item should be used only in 

accordance with operation and installation manual.

The item is subject to qualified professional installation with the authorized service centers. The fitter of the 

system must fill in the certificate of installation, enclosed to the set box.

The malfunctioned during the warranty period through the fault of the manufacturer composite devices of 

the system are subject to replacement or repair by the fitter (manufacturer or a company, accomplishing complex 
maintenance).

The consumer is deprived of the right to the after-sales service in the following cases:
• upon the warranty period expiry;
• in case of the violation of the rules of installation, operation, transportation and storage;
• in case of the presence of the mechanical damages of the external components of the system appeared 

after the moment of sale, including the fire impact, breakdown, penetration of the aggressive liquids and water, 
misconduct;

• in case of the presence of the damages caused by improper setting or adjustment;
•  in  case  of  the  system’s  composite  devices  replacement  for  those  which  are  not  recommended  by  the 

manufacturer;

• if the factory sealing is broken;
• in case of the duly filled in installation certificate or the warranty counterfoil absence;
Warranty operation life is 1 year from the date of sale, but not longer than 1,5 years since the moment of 

manufacture.

This warranty does not apply to the batteries of remote control units, which have a natural limited service life.
Repair and maintenance of the system with an expired warranty period should be performed for the account 

of consumer according to the separate agreements between the supplier/fitter and the consumer. Resolutions of 
the manufacturer (fitter) in respect of the questions, connected with the claims are final. The defective parts which 
have been replaced are the property of the manufacturer (fitter).

Summary of Contents for G303

Page 1: ...Gorgon G3O3...

Page 2: ...ssenger compartment light activation delay 8 Car tracing feature 8 Panic mode 8 Timer channel 1 8 Timer channel 2 8 Distant radio alert channel 9 System control via a secret code 9 Technical maintenan...

Page 3: ...ccumulator led out to the mass ground The system complies with the climatic requirements U 2 1 N 2 1 according to GOST 15150 69 standard and is intended for the use within the environment temperature...

Page 4: ...security mode Not more than 20 Main unit supply voltage V 9 15 Radio channel frequency Hz 433 92 Frequency deviation Hz 433 075 Hz to 434 79 MHz Emission power Wt Less than 10 Operative temperature ra...

Page 5: ...er than 1 5sec 1 Arming with a built in shock sensor deactivation Two signals of the parking lights 1 pause not longer than 1 5sec 3 Arming with an external double area sensor deactivation Three signa...

Page 6: ...area sensors deactivation perimeter se curity press button 1 of the remote unit release it within a 1 5 seconds period and then press buttons 1 3 simultaneously The system will produce four signals of...

Page 7: ...arm mode and to stop generating all alert signals just press any button of the remote control unit If the warning level of the system s sensor has been activated three times consequently the system wi...

Page 8: ...ess and then release the remote s button 1 press and hold buttons 1 2 of the remote control unit simultaneously release buttons 1 2 upon the Panic mode activation Generation of the sonic signals in Pa...

Page 9: ...cret code you have an option to switch between the following system modes from armed or alert modes to disarmed mode from immobilizer turned on to immobilizer turned off from disarming with ignition t...

Page 10: ...green flashes whereupon the indicator goes down Press the VALET button a corresponding number of times to choose the required level of program ming The interval between the pressings should not exceed...

Page 11: ...channel activation during disarming PROHIBITED ALLOWED 5 3 Timer channel on off by the remote s buttons 1 3 PROHIBITED ALLOWED 5 4 Timer channel work duration max 40 minutes 1 second Work of the dista...

Page 12: ...the remote control unit Change the preset secret code for the safety sake before you start using the system Sublevel 2 1 The LED is not alight Enter the first digit of a secret code by entering the VA...

Page 13: ...k sensor s operation threshold by alert level This adjustment is identical to the setting described in Sublevel 8 1 At the VALET button pressing the system stores a current setting and is waiting for...

Page 14: ...transportation and storage in case of the presence of the mechanical damages of the external components of the system appeared after the moment of sale including the fire impact breakdown penetration...

Page 15: ...___ CERTIFICATE OF INSTALLATION I undersigned ___________________________________________ the professional fitter verify that the installation of the car alarm system described below was performed by...

Page 16: ...16 Gorgon G3O3 Made in Russia...

Reviews: