GMS SERIES
OM-04386
PAGE C-3
OPERATION
Packing pumps
must
leak slightly
to cool and lu
bricate the shaft and to allow the shaft to turn freely.
Wait until the pump has run long enough to reach
its normal operating temperature to adjust the
gland nuts. Adjust the nuts only tight enough to re
duce excessive leakage.
PRESSURE RELIEF VALVE
ADJUSTMENT
Some pumps are not provided with a pressure re
lief valve. A pressure relief valve must be installed
on the pump or in the discharge piping to ensure
safe operation. Otherwise, the pump may be dam
aged and personnel injured.
If operating at high temperatures, allow the
pump to completely cool before attempt
ing any adjustments.
Cracking Pressure
Cracking pressure is the pressure at which the
pressure relief valve first begins to open and by
pass fluid. The nominal cracking pressure of the re
lief valve provided with this pump is set at the facto
ry and is indicated on the tag attached to the relief
valve.
If the nominal cracking pressure set at the factory
must be changed, see Table E‐2 and instructions in
Section E ‐ MAINTENANCE AND REPAIR
.
Complete By‐pass Pressure
Complete by‐pass pressure is the maximum pres
sure the pump will see when all the pumped fluid is
being by‐passed through the pressure relief valve.
This pressure will vary depending on the cracking
pressure setting, liquid viscosity, and pump speed
(pump capacity).
To determine the complete by‐pass pressure, refer
to the pump performance chart or consult the fac
tory.
Do not remove the adjusting screw jam
nut; with the jam nut removed the relief
valve spring(s) can be compressed too
far for the valve to
open. If the valve
does not open, excessive pressure can
develop, causing damage to the pump
and possible injury to personnel.
STOPPING
If the pump will be out of service for an extended
length of time, particularly when handling non‐lu
bricating liquids, drain the system and flush the
pump and piping with an oil‐based preservative to
protect close‐tolerance pump parts.
When handling liquids that solidify when at rest
(tar, glue, etc.), flush the pump and piping with an
approved solvent compatible with the pump com
ponents and the liquids being pumped.