VGH SERIES
OM-06114
MAINTENANCE & REPAIR
PAGE E - 10
FILL
ONLY
THROUGH
CONSTANT
LEVEL OILER
DO NOT
FILL
THROUGH
VENT PLUG
Figure 3. Lubricating Bearing Cavity
Do not
fill the bearing cavity through the vent plug
in the top of the housing. This will result in over‐fill
ing, and can cause leakage, excessive heat build
up and/or premature bearing failure.
Check the oil level regularly through the constant
level oiler and add oil as required.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Power Source
Consult the literature supplied with the power
source, or contact your local power source repre
sentative.