3.2 COMBINED COMMAND
To save time and SMS resource on configuration, user can apply combine
command, in which there is more than one command, to operate configuration.
The combine command would begin with user password, which is followed by
commands (commands order is flexible). Format is as follow:
3.1.12
3.1.13
TZN:8:00
IMM:0
TZN;8:00
IMM;0
TZN
IMM
Time zone
setting
Immobilizer
Output
"0" : close
"1”: open device send power
cut command or the device is
disconnection, cut power of
vehicle.
Set local time zone parameter
from ‐12:00 to 12:00, Negative
represent western time zone,
positive represent east eastern
time zone
Default : 0 : 00
Remarks
Reply
Command
Ctrl Word
Description
Sr.
First command
Second Command
Pw
Command
word
Command
word
Parameter
Parameter
Parameter
,
,
;
;
;
If there is duplication of the same command in the same combine command, just
the last piece of command would be processed; if there is error in the command,
the command with error would be discarded, and device would only confirm
setting of correct commands with no error warning. If all the commands are error,
an alarm will be sent. All setting commands, except user No. setting command
under the condition of the user number has never been changed, can be set by
combine command.
Example
:
1234,UUM;30M;G;T,UPW;1234