8
GMC-I Gossen-Metrawatt GmbH
1.5 Technical Data
1.5.1
General Data
Output
Regulator type
Primary switched-mode regulator
Operating modes
Adjustable constant voltage / constant
current source with automatic sharp
transition
Output insulation
Floating output with “safe electrical
separation” from the mains input and
computer interfaces
Max. allowable potential, output to ground:
120 V
Capacitance, output to ground (housing)
Series 62 N: 500 W / 1000 W: typ. 90 nF
Series 64 N: 2000 W / 3000 W: typ. 180 nF
Output operating range
Analog Interface
Functions
– Auto-sensing mode
– Programmable trigger input
– Voltage control input (0 ... 5 V)
– Current control input (0 ... 5 V)
– Voltage monitor output (0 ... 10 V)
– Current monitor output (0 ... 10 V)
– Master-slave parallel operation
– Master-slave series operation
IEC 625 – IEEE 488 interface (common option with RS 232, variant 2)
Interface functions
(see chapter 6.2 for description of functions.)
SH1
– SOURCE HANDSHAKE
AH1
– ACCEPTOR HANDSHAKE
T6
– TALKER
L4
– LISTENER
TE0
No extended talker function
LE0
No extended listener function
SR1
– SERVICE REQUEST
RL1
– REMOTE / LOCAL
DC1
– DEVICE CLEAR
PP1
– PARALLEL POLL
DT1
– DEVICE TRIGGER
C0
– No controller function
E1 / 2
– Open collector driver
Codes / formats
per IEEE 488.2
Max. setting rate
approx. 40 settings per second
Max. sampling rate approx. 15 measurements per second
V.24 – RS 232C Interface (optional, variant 1 or 2)
Transmission mode half-duplex, asynchronous
Baud rate
110 ... 19,200 baud, adjustable
Codes / formats
Per IEEE 488.2
Max. setting rate
Approx. 2 settings per second
Max. sampling rate Approx. 2 measurements per second
Power Supply
Line voltage
62 N:
230 V ~ +10 / –15%,
47 … 63 Hz
64 N:
3 x 400 / 230 V ~ +10 / -15%,
47 … 63 Hz
Inrush Current
Max. 50 A
S
Fuse
62 N:
1 ea. M 15 A / 250 V
(6.3 x 32 mm), UL
64 N:
3 ea. M 15 A / 250 V
(6.3 x 32 mm), UL
Electrical Safety
Safety class
I
Overvoltage
category
II for mains input
I for output and interfaces
Fouling factor
2
Earth leakage
current
62 N:
<3 mA
eff
64 N:
<1 mA
eff
Electrical Isolation
Rated Voltage
Test Voltage
Output – mains
280 V
eff
4 kV ~ (type test)
Output – bus /
ground
120 V
S
1.5 kV ~
Mains – bus /
ground
230 V
eff
2.2 kV –
Bus – ground
No electrical isolation
IEC 61010-1: 1990 + A1: 1992
DIN EN 61010-1: 1993
VDE 0411-1: 1994
DIN VDE 0160: 1988 + A1: 1989 class W1
VDE 0805: 1990
EN 60950: 1992
Protection
IP 00 at device terminals and
interface terminals
IP 20 at housing
Electromagnetic Compatibility
Product standard
EN 61326-1: 1997 + A1: 1998
Interference
emission
EN 55022: 1998 class A
Interference
immunity
EN 61000-4-2: 1995, feature B
EN 61000-4-3: 1996 + A1: 1998, feature A
EN 61000-4-4: 1995, feature C
EN 61000-4-5: 1995, feature B
EN 61000-4-6: 1996, feature B
EN 61000-4-11: 1994, feature A
Ambient Conditions
Climatic category
KYG per DIN 40 040
Temperature range Operation:
0 to 40° C
Storage:
–20 to +70° C
Relative humidity
Operation:
≤
75%,
no condensation allowed
Storage:
≤
65%
Cooling
With integrated fan
(2-step temperature control)
Inlet vent:
side panel
Outlet vent:
rear panel
Operating noise
Noise pressure level at a distance of 30 cm
with fan set to low / high
62 N:
64 N:
front
18 / 28 dBA
20 / 30 dBA
rear
23 / 35 dBA
26 / 38 dBA
left and right 20 / 30 dBA
26 / 36 dBA
U / V
U
nominal
0,5
P
nominal
P
typ
P
dyn
(< 5 ms)
0.5 I
nominal
I
nom
0
I / A
Voltage
Setting Range
Current
Setting Range
P
typ
∼
1.3 x P
nominal
U
nominal