Applications

METRA

Hit

â

28S and 29S multimeters are high performance pre-

cision instruments for the lab, service and training. 
With a display range of 300,000 digits as well high level accuracy 
and long-term stability, they fulfill all calibration and R&D labora-
tory demands. Battery operation allows for on-site precision ser-
vicing and calibration.

Features

Convenient Triple Display

The current measurement value, as well as two other values, are 
updated and displayed, e.g. minimum and maximum value. The 
usual switching back and forth between display values is no 
longer necessary. 

Display resolution

 

for the main display value can 

be varied from 4¾ places for AC to 5¾ places for DC 
(METRA

Hit

â

29S: from 2¾ to 5¾ places). The 

measurement rate

adjustable from 1 ms to 0.5 s, allows for high-speed recorder, 
precision data logger and mean value recorder functions with the 
help of METRAwin

â

10/METRA

Hit

â

 (optional PC software).

High Resolution and Precision

5¾ places, or 309,999 digits, allow for cost effective calibration of 
tested devices and components, as well as precise reference 
measurements.

Effective Value for Distorted Waveforms

The implemented measurement process provides for effective 
value measurement (TRMS) independent of the waveform up to 
100 kHz.

Additional Functions

Continuity testing with acoustic signal, event counting (number of 
events and event durations), counts zero crossings, stopwatch, 
data comparison and wide-range capacitance measurement. The 
integrated temperature measurement function allows for the con-
nection of thermocouples and platinum resistance thermometers.

Overload Protection

The instrument is protected from overload in the voltage range. 
Acoustic signalling occurs if measuring range limits are exceeded.
The FUSE display indicates a defective fuse in the current range.

Calibration

METRA

Hit

â

28S and 29S multimeters are shipped with a 

DKD calibration certificate. They can be automatically calibrated 
with the CS92E calibration system via the RS232 data interface.

Infrared Measurement Data Transmission *

These devices include a serial, duplex data interface for remote 
control and measurement value transmission via infrared light.

METRA

Hit

â

28S and 29S

300,000 digits and triple display 

Precision multimeter (V, dB, A, 

, F, Hz, F, °C/°F)

Current measurement with (clip-on) current transformer: 
a transformation ratio of 1000:1 or 10000:1 
is utilized for display purposes

Integrated quartz movement
for recording of MIN/MAX values relative to real-time

AUTO SELECT
automatic measured quantity recognition (V, 

 and F)

METRA

Hit

â

29S

Power and energy measurements (W, VAr, VA, Wh, PF)
with analog signals or energy measurement with pulses, 
current measurement value, mean values and peak
power values are displayed

Power disturbances recording

Large, 128 kB measurement value memory

Summary of Contents for MetraHit 28s

Page 1: ...asurement TRMS independent of the waveform up to 100 kHz Additional Functions Continuity testing with acoustic signal event counting number of events and event durations counts zero crossings stopwatch data comparison and wide range capacitance measurement The integrated temperature measurement function allows for the con nection of thermocouples and platinum resistance thermometers Overload Prote...

Page 2: ...e events is stored to memory and can be queried at a later point in time The type of event the time of its occurrence and its duration except for pulses are displayed If memory mode is deactivated approximately 250 events can be stored to volatile memory and read out at the display These data remain in storage until the instrument is switched to a different operating mode If memory mode is activat...

Page 3: ...02 0 005 5 0 2 30 1000 V 10 mV 100 mV 10 MΩ 5 MΩ 50 pF 0 02 0 005 5 0 2 30 dB see table following page same as V 0 1 dB 11 dB Volt Drop approx for upper range limit B 5 A 300 µA 1 nA 10 nA 160 mV 160 mV 0 05 0 02 5 0 5 30 0 36 A cont A 3 mA 10 nA 100 nA 160 mV 160 mV 0 05 0 01 5 0 5 30 20 mA 30 mA 100 nA 1 µA 170 mV 170 mV 0 02 0 01 5 0 5 30 0 05 0 01 5 300 mA 1 µA 10 µA 300 mV 300 mV 0 1 0 01 5 0...

Page 4: ... 1050 V mA 0 36 A A 10 A DC AC eff sine V mA continuously 10 A cont 12 A 5 min 16 A 30 s 10 mW 1 µW 100 mW 10 µW 1 W 0 1 mW 10 W 1 mW 100 W 10 mW 1 kW 0 1 W 10 kW 1 W Meas Quantity Meas Range Inherent Deviation of rdg D 15 Hz 45 Hz 45 Hz 65 Hz 65 Hz 1 kHz Active power 300 mA 10 A 1 3 20 1 20 3 20 Reactive power 2 5 20 1 5 20 3 20 Apparent power 1 2 20 1 20 1 2 20 Power factor 0 02 1 2 2 1 2 2 2 hr...

Page 5: ...ith VDI VDE 3540 Elevation to 2000 m Mechanical Design Protection Devices IP 50 Connector jacks IP 20 Dimensions 84 mm x 195 mm x 35 mm Weight METRAHitâ28S approx 350 gr with batteries METRAHitâ29S approx 405 gr with batteries Influence Variable Sphere of Influence Meas Quantity Meas Range 1 Influence Error 2 Measuring Quantity Waveform Crest factor CF 1 3 V A 1 of rdg 3 5 3 of rdg Influence Varia...

Page 6: ...nual measuring range selection 18 Relative value 19 Measurement with clip on current transformer is active Transformation ratio of 1000 1 or 10000 1 is taken into consideration Display Refresh V DC AC DC A Ω EVENTS AC DC Count 2 per second V AC EVENTS AC 1 per second W VA VAr Wh 1 v second Hz C Pt100 1000 1 to 2 per second C J K 0 5 per second Fusing Fuse for ranges up to 300 mA FF UR 1 6 A 1000 V...

Page 7: ...as well as via system time Data Logger 1 Acquired measurement data from up to 10 channels are dis played at the monitor in an easy to read table in numeric format Multimeter 2 Transmitted measurement data from up to 4 freely selectable channels appear at the monitor in digital format with an additional analog scale display in online operation or as an analog pointer instrument with optional digita...

Page 8: ...829 carrying case WZ11 clip on current transformer 15 180 A 1 mA 1 A and measuring cables Electric Set GTZ 3236 000 R0001 Clip on current transformer 30 mA 150 A 1000 1 Frequency range 50 500 Hz Clip jaw opening cable diameter max 15 mm WZ12D D Z219D Clip on current transformer 4 500 A 1 mA A with cable and protective circuit Clip jaw opening cable diam max 30 mm Z3511 GTZ 3511 000 R0001 Clip on c...

Reviews: