GMC-I Messtechnik GmbH
57
Technical Data
1)
15 ... 45 ... 65 Hz ... 10 (5) kHz sine. See following page for influences.
2)
At 0
... + 40
C
3)
Display of up to max. 5.1 V, “OL” in excess of 5.1 V.
4)
Applies to measurements at film capacitors and battery operated
5)
Lowest measurable freq. for sinusoidal meas. signals symmetrical to
zero point
6)
Overload capacity of the voltage measurement input: power limiting:
frequency x max. voltage 3 x 10
6
V x Hz @ U > 100 V
7)
Overload capacity of the current measurement input:
See current measuring ranges for maximum current values.
8)
Input sensitivity, sinusoidal signal, 10% to 100% of the voltage or current
measuring range; limitation: up to 30% of the range at up to 100 kHz in
the mV measuring range, 30% of the range in the 3 A measuring range.
The voltage measuring ranges with max. 30 kHz apply in the A mea-
suring range.
9)
Plus sensor deviation
10)
With ZERO function active
11)
Residual value of 1 to 10 d with short circuited terminal tips,
exception: mV /
A range of 1 to 35 d at zero point due to the TRMS converter
12)
10 minute cool-down period
Key:
R = meas. range, d = digit(s), rdg. = measured value (reading)
Meas.
Func-
tion
(input)
Measuring Range
Resolution
at Upper Range Limit
Intrinsic Uncertainty
under Reference Conditions
Overload
Capacity
2)
3000
Value
Time
Discharge resist.
U
0 max
(... % rdg. + ... d)
F
30.00
nF
10 pF
10 M
0.7
V
1 + 6
4)
with ZERO function active
1000 V
DC
AC
RMS
Sine
max. 10 s
300.0
nF
100 pF
1 M
0.7
V
1 + 6
4)
3.000
F
1 nF
100 k
0.7
V
1 + 6
4)
30.00
F
10 nF
12 k
0.7
V
1 + 6
4)
300.0
F
100 nF
3 k
0.7
V
5 + 6
4)
f
min
5)
(... % rdg. + ... d)
Hz (V)/
Hz (A)
Hz (A
)
300.0
Hz
0.1 Hz
1
Hz
0.1 + 2
8)
Hz (V)
6)
:
Hz(A
)
6)
:
1000 V
Hz (A):
7)
max. 10 s
3.000 kHz
1 Hz
30.00 kHz
10 Hz
10
Hz
Hz (V)
300.0 kHz
100 Hz
100
Hz
(... % rdg. + ... d)
9)
C
Pt 100
– 200.0 ...
+850.0
C
0.1
C
0.5 %+ 15
1000 V
DC/AC
RMS
Sine
max. 10 s
Pt 1000
– 150.0 ...
+850.0
C
0.5 %+ 15
K
(NiCr-Ni)
– 250.0 ...
+1372.0
C
1% + 5 K