The housing top can be tipped up after removing the two bottom screws with the included tool (stiff wire,
approx. 25 cm long) in order to work on the installed SMARTCONTROL.
Remove the bottom two screws and tip up the housing top to this end. Now insert one end of the tool into the
threaded drill hole for the bottom housing screw in the SMARTCONTROL base plate at either side of the
SMARTCONTROL – from the outside.
Insert the other end of the tool into the drill hole for the bottom screw in the housing top after it has been tipped
up.
5.3.2.
Wall Mounting the IP 65 SMARTCONTROL
The standard version of the IP 65 housing has the following dimensions: approx. 380 x 380 x 210 mm (W x H x D).
The 4 holes in the housing are used to mount the SMARTCONTROL. Remove the right-hand cable duct cover in
order to expose all four mounting holes.
In the case of special orders, please check the dimensions of the IP 65 housing.
5.4.
Power Supply Cable for the SMARTCONTROL IP 65
Warning:
Cables must be voltage-free.
Note:
The cables must be led in from the top and are secured by
means of heavy duty cable glands.
It must be assured that the cables are long enough to reach
the connector terminals.
38 cm
34 cm
34 cm
38 cm
The box must be securely
mounted with 4 suitable
screws and anchors,
depending upon substrate and
material.
Box Mounting Hole
Diameter:
Approx. 8.2 mm
2 cm
2 cm
Housing
Rear Panel
2 cm
2 cm
PCB
Terminal
Block
Heavy-Duty Cable Gland
Cable Duct
Ground Bus Bar