All Rights reserved, No Spreading without GOSUNCN Permission
43
Hardware Development Guide
ME3616
4.4.
RF
R
ECEIVING
S
ENSITIVITY
Table 4-4 RF Receiving Sensitivity(RSSI)
mode
Frequency
Test(Unit:dBm)
NB-IoT
LTE FDD Band 1
-114
LTE FDD Band 3
-114
LTE FDD Band 5
-115
LTE FDD Band 8
-115
LTE FDD Band 20
-115
LTE FDD Band 28
-115
Note:
The test Receiving Sensitivity is tested through instrument without re-transmission.
4.5.
E
LECTROSTATIC
D
ISCHARGE
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject to ESD handling
precautions that typically apply to ESD sensitive components. Proper ESD handling and packaging procedures must be applied
throughout the processing, handling and operation of any application that incorporates the module.
The following table shows the module electrostatics discharge characteristics.
Table 4-5 ESD characteristic
Tested Points
Contact discharge
Air Discharge
Unit
All antenna
interfaces
±2
±4
kV
Other interfaces
±2
±4
kV