All Rights reserved, No Spreading without GOSUNCN Permission
47
Hardware Development Guide
ME3616
6.
R
ELATED
T
EST
&
T
EST
S
TANDARD
6.1.
T
ESTING
R
EFERENCE
The related tests of MODULE comply with the IEC standard, including the equipment running under high/low temperature,
storage under high/low temperature, temperature shock and EMC. Table 6-1 is the list of testing standard, which includes the
related testing standards for MODULE.
Table 6-1 Testing Standard
NOTE:
IEC: International Electro technical Commission;
GB/T: Recommended national standard
Test Standard
Document Reference
IEC6006826
Environmental testing-Part2.6: Test FC: Sinusoidal Vibration
IEC60068234
Basic environment testing procedures part2.
IEC60068264
Environmental testing-part2-64: Test FH: vibration, broadband random and guidance.
IEC60068214
Environmental testing-part 2-14: Test N: change of temperature
IEC60068229
Basic environmental testing procedures-part2: Test EB and guidance.
IEC6006822
Environmental testing-part2-2: Test B:dry heat
IEC6006821
Environment testing-part2-1: Test A: cold.
GB/T 15844.2
MS telecommunication RF wireless phone-set environment requirement & experimental method – part 4: Strict level of
experimental condition
GB/T 2423.17
Basic environment experiment of electronic products-Experiment Ka: Salt mist experiment method
GB/T 2423.5
Basic environment experiment of electronic products-Part2: Experiment method Try Ea & Introduction: Shock
GB/T 2423.11
Basic environment experiment of electronic products-Part2: Experiment method Try Fd: Broad frequency band random vibration
(General requirement)
TIA/EIA 603 3.3.5
TIA Standard-part3-5:Shock Stability
6.2.
D
ESCRIPTION OF
T
ESTING
E
NVIRONMENT
The working temperature range of MODULE is divided into the normal working temperature range and the extreme working
temperature range. Under the normal working temperature range, the testing result of RF complies with the requirements of 3GPP
specifications, and its function is normal. Under the extreme temperature range, the RF index basically complies with the 3GPP
specifications, and the quality of data communication is affected to a certain extent, but its normal function is not affected. MODULE
has passed the EMC test. Table 6-2 is the requirement for the testing environment, and Table 6-3 lists out the instruments and
devices that might be used during the test.
WARNING:
Table 6-2 lists the extreme working conditions for the Module. Using the Module beyond these conditions
may result in permanent damage to the module.